3 explicit messaging, Co mm u n ic a tin g with th e gt2 s e rie s – KEYENCE DL-DN1 User Manual
Page 61

3-3 Explicit Messaging
3-31
3
Co
mm
u
n
ic
a
tin
g
with
th
e
GT2
s
e
rie
s
- DeviceNet Compatible Network Unit DL-DN1 User’s Manual (GT2) -
Nx10+4
64
Group-4 entry count
R
29
65
Calculation mode/calculation setting
*12
*13
R/W
0
00+m: Do not use calculation function
10+m: Use calculation function
20+m: Calculation-only mode
0: Maximum
1: Minimum
2: Flatness
3: Mean
4: Standard difference
5: Torsion
6: Warp
7: Thickness
66
Detection mode
R/W
0
0: Standard
1: NG hold
2: Peak
3: Bottom
4: Peak-to-peak
67
Hold update method
R/W
0
0: Timing
1: Always update
68
Response time
R/W
3
When the connected
sensor head is
GT2-H***/A***
When the
connected sensor
head is GT2-P***
0: HSP (3.0 ms)
HSP (12 ms)
1: 5 ms
20 ms
2: 10 ms
40 ms
3: 100 ms
400 ms
4: 500 ms
2000 ms
5: 1000 ms
4000 ms
69
Timing type
R/W
0
0: External timing input
1: Rising self
2: Falling self
6A
Self timing level
R/W
+000.5000 -199.9999 to +199.9999
6B
Self-timing delay type
R/W
0
0: Static hold
1: Delay timer
6C
User-specified delay time
R/W
1000
0000-9999
6D
Static hold delay stable determination
R/W
0
0: Default
1: User
6E
Static hold delay stable range
R/W
+000.0100 +000.0000 to +199.9999
6F
Measurement increase/decrease
direction
R/W
0
0: Normal
1: Reverse
70
Multiplier
R/W
001.0
000.1 to 100.0
71
Output mode
R/W
0
0: NO
1: NC
InstID
(DEC)
AttrID
(HEX)
Name
Description Attribute
Default
value
Parameter range