1 dl-dn1 overview, Overview, Types and number of connectable sensor amplifiers – KEYENCE DL-DN1 User Manual
Page 12: Dl-dn1 overview -2, Dl-dn1 overview

1-2
1
Bef
o
re
U
s
in
g
- DeviceNet Compatible Network Unit DL-DN1 User’s Manual (GT2) -
1-1
DL-DN1 Overview
The DL-DN1 operates as a slave unit of DeviceNet communication. Using DeviceNet
communications, the sensor amplifiers and other units connected to the DL-DN1 can
transmit their ON/OFF control signals and current values as communication data to a
PLC or other equipment.
The DL-DN1 supports DeviceNet I/O communication (polling) and explicit messaging.
I/O polling enables data communication without the need of a ladder program. Explicit
messaging allows for reading/writing sensor amplifier parameters and issuing motion
commands to the sensor amplifiers.
System configuration example
Number of Connectable Sensor Amplifiers
*
Up to 11 sensor heads can be connected by adding a head connection board to
the main unit.
Overview
D-bus compatible sensor amplifier
PLC or other host device
(DeviceNet master unit)
DL-DN1 (This unit)
DeviceNet slave unit
KV
-DN20
MS
NS
ON
TERM.
Types and Number of Connectable Sensor Amplifiers
Name
Amplifier
form
Main unit
Expansion
unit
Maximum number of
connectable units
GT-2
Series
DIN rail
mounting type
GT2-
71(M)(C)N
GT2-
71(M)(C)P
GT2-
72(M)(C)N
GT2-
72(M)(C)P
15
(1 main unit, 14 expansion units)
Panel
mounting type
GT2-75N
GT2-75P
GT2-76N
GT2-76P
15
(1 main unit, 14 expansion units)
Large display
type
GT2-100N
GT2-100P
1
(1 main unit)*