Locking sensor amplifiers, Locking sensor amplifiers -26 – KEYENCE DL-DN1 User Manual
Page 56

3-3 Explicit Messaging
3-26
- DeviceNet Compatible Network Unit DL-DN1 User’s Manual (GT2) -
3
Co
mm
u
ni
c
a
ting
w
ith t
he G
T
2
s
er
ie
s
Response format
• When normal (for writing response data of WORD, UINT, or DINT type)
• When abnormal
The following formats are used to activate the key lock on all sensor amplifiers
connected to the DL-DN1.
Command format
Service data
Error code 0Eh is returned if the DL-DN1 is connected with any sen-
sor amplifier that does not support key lock or full key lock. (The set-
tings of such non-supported sensor amplifiers remain unchanged.)
Response format
• When normal
• When abnormal
Responder
node address
Service Code
0004h
**h
90h
0000h
Response data
Number of received bytes
Responder
node address
Service Code
0004h
**h
94h
FF**h
Response data
(Error code)
Number of received bytes
Locking Sensor Amplifiers
Service data
Action
Description
0000h
Deactivate key lock
Deactivates key lock.
0001h
Activate full key lock
Activates full key lock.
0002h
Activate key lock
Activates key lock.
Destination
node address
Service
Code
**h
4Ch
0067h
0000h
(See below)
Class ID
Instance ID
Service data
Point
Responder
node address
Service Code
0004h
**h
CCh
0000h
Response data
Number of received bytes
Responder
node address
Service Code
0004h
**h
94h
FF**h
Response data
(Error code)
Number of received bytes