DIGITS: Displays the digital thickness value using a larger font size. This view is
useful when the TI-MVX is being used as a basic thickness gauge.
Once the view has been selected according to the application requirements, the
delay and width of the screen will potentially need to be adjusted, if the view has
been set to RF, RECT, or BSCAN. Use the following steps to adjust these set-
tings directly from the measurement screen as follows:
Adjusting the Delay & Width
1) Press the MEAS key once to activate the measure menu items. Press the
MEAS key multiple times to move right and the ESC key multiple times to move
left, until the either the DELAY or WIDTH cell is highlighted.
2) Use the UP, DOWN, LEFT, or RIGHT arrow keys to scroll the DELAY and
WIDTH values.
3) Repeat steps 1 & 2 until the range is correctly being displayed.
Alternatively, the DELAY and WIDTH values can be changed using the Digit Edit
Box as follows:
1) Press the MEAS key once to activate measure menu items. Press the MEAS
key multiple times to move right and the ESC key multiple times to move left,
until the either the DELAY or WIDTH cell is highlighted.
-9-
8) Use the CLR key to backspace if necessary.
9) Repeat steps 6 -8 until the Comments are
completed.
10) Press the UP or DOWN arrow key to high-
light SAVE CHANGES, and the OK key to
activate the confirmation screen.
11) Press the OK to save the changes or the
ESC key to cancel editing the grid parameters.
12) Press the MEAS key to return to the
measurement screen.
10.7 Changing the active grid (Open)
The user may have transferred grid templates from
a PC to the TI-MVX, or setup grids using the TI-MVX
at an earlier time. The name of the currently active
grid is always displayed at the bottom of the Hot
Menu Items in measurement mode. It’s not only
important to recognize what grid is currently active,
but also be able to change the active grid at any
time. The following procedures outline this process:
1) Press the MENU key once to activate the menu
items tab. Press the MENU key multiple times to tab
right and the ESC key multiple times to tab left until
the DATA menu is highlighted and displaying the
submenu items.
-72-