Power-on self-test messages – Compaq Deskpro 2000 Series User Manual
Page 170
C-4
Error Messages
Writer: Holly Jahangiri Saved by: Alyce Klingler-Castle Saved date: 06/10/97 3:54 PM
Pages: 6 Words: 992 Template: d:\95office\templates\commapp.dot
File Name Appc Part Number 278019-002
Power-On Self-Test Messages
Continued
Message
Beeps*
Probable Cause
Recommended Action
1152-System Board
Comm Port 2
Address Assignment
Conflict
2S
Both external and internal
serial ports are assigned to
COM2.
Run Computer Setup or Windows NT or
Windows 95 utilities.
1721-SMART SCSI
Hard Drive detects
imminent failure
None
Hard drive is about to fail.
Backup contents and replace hard
drive.
1771-Primary Disk
Port Address
Assignment Conflict
2S
Internal and external hard
drive controllers are both
assigned to the primary
address.
Run Computer Setup or Windows NT or
Windows 95 utilities.
1772-Secondary
Disk
Port Address
Assignment Conflict
2S
Internal and external hard
drive controllers are both
assigned to the secondary
address.
Run Computer Setup or Windows NT or
Windows 95 utilities.
1780-Disk 0 Failure
None
Hard drive/format error.
Run the Configuration and Diagnostics
utilities.
1781-Disk 1 Failure
None
Hard drive/format error.
Run the Configuration and Diagnostics
utilities.
1782-Disk Controller
Failure
None
Hard drive circuitry error.
Run the Configuration and Diagnostics
utilities.
1790-Disk 0 Failure
None
Hard drive error or wrong
drive type.
Run the Configuration and Diagnostics
utilities.
1791-Disk 1 Failure
None
Hard drive error or wrong
drive type.
Run the Configuration and Diagnostics
utilities.
1792-Secondary
Disk Controller
Failure
None
Hard drive circuitry error.
Run the Configuration and Diagnostics
utilities.
1793-Secondary
Controller or Disk
Failure
None
Hard drive circuitry error.
Run the Configuration and Diagnostics
utilities.
* L = Long, S = Short
continued