Appendix 1 function setting list, Rl-ts series operation manual 87, Additional – Rice Lake TS Series, Rice Lake Weighing Systems - Operation Manual User Manual
Page 91

RL-TS Series Operation Manual 87
Appendix 1
Function Setting List
Additional
Animal weighing selected
“
Cumulate
function” or
“Cumulate function
+ Limit function”
selected
(Continued on next page.)
(Select output data)
(Auto output)
(Auto tare setting)
(Output a hold value)
(Weight variation range of hold)
Animal-only response speed
Additional function disabled
Cumulate function selected
Limit function selected
Cumulate function + Limit function
(Condition)
(Range to cover)
(Point scale)
(Judge by)
(Buzzer when LO is
judged)
(Buzzer when OK is
judged)
(Buzzer when HI is
judged)
(How to indicate
results)
(Addition operation)
Water
Not water
Only a specific gravity value
Specific gravity, weight, actual water temperature or
medium density
Output disabled
Auto output once after a specific gravity measurement
OFF
ON
OFF
ON (Auto output once after weight hold)
20 times the minimum readability
50 times the minimum readability
100 times the minimum readability
Fast
Middle
Slow
Always judge (even when the balance is unstable)
Judge only when the balance is stable (not judge when the balance is
unstable)
Detect when the limit is exceeded by more than five divisions
Detect both when the limit is exceeded and when it is not reached
1-point scale (OK/LO are judged)
Upper and lower limits (HI/OK/LO are judged)
Judge by absolute value
Judge by deviation value
Buzzer not beeped for rank LO
Buzzer beeped for rank LO
Buzzer not beeped for rank OK
Buzzer beeped for rank OK
Buzzer not beeped for rank HI
Buzzer beeped for rank HIK
HI/OK/LO
2-point bar graph (Available only for 2-point scale)
Cumulate
Net addition
“
Limit function” or
“Cumulate function
+ Limit function”
selected
Auto-zero
Stability judgment
Response speed
Interface
When 1, 2, or 3 is
selected in “”
When 3 is selected in
“”
When 1, 2, or 3 is
selected in “”
When 2, or 3 is
selected in “”
Disabled
Enabled
Wide (Mild)
Narrow (Strict)
Measurement by consecutive weighings
Fast
Slow
Stop input/output
Numeric 6-digit format
Numeric 7-digit format
Extended numeric 7-digit format
(Output control)
(Baud rate)
(Parity)
(Data length)
(Stop bit)
(Unused high order
digits)
(Response
commands)
* Select “1” or ”2” if using a supported printer.
Stop output.
Output continuously at all times.
Output continuously if stable (stop output if unstable).
Output once when the [Print] key is pressed (whether the balance is
stable or unstable).
Output once when the balance is stable.
Output when a sample is lifted to cause the display to indicate a value below 0, and
then another sample is placed to make the balance stable.
Output once when the balance is stable.
Stop output when unstable. Output once when the balance is stabilized again even if it
is not reloaded (the output includes zero).
Output once when the balance is stable.
Output continuously when unstable. Output is stopped after a single output when the
balance is stable even if it is not reloaded.
Output once when the [Print] key is pressed if the balance is stable
1200 bps
2400 bps
4800 bps
9600 bps
19200 bps
None
Odd
Even
7 bit
8 bit
1 bit
2 bit
Embed 0 (30H)
Embed space (20H)
A00, Exx
ACK, NAK
A star () denotes an initial value.
A star () denotes an initial value.
A star () denotes an initial value.
(Continued on next page.)
Span
adjustment/test
Bar graph
Auto power off
Auto backlight off
Unit setting
Minimum readability
Unit setting
Minimum readability
i
ISO/GLP/GMP compliance
(Unit A)
(Unit A)
(Unit B)
(Unit B)
When 1 is selected in
CAL operation disabled
Span adjustment with external weight
Span test with external weight
Not displayed
Displayed
Disable (for continuous use)
Enable (The power is turned off five minutes later.)
* Enabled only when the balance is powered
by batteries
Disable (for continuous use)
Enable (The backlight goes off if the balance is not used for about three minutes.)
g (gram)
kg (kilogram)
ct (carat)
oz (ounce)
lb (pound)
ozt (troy ounce)
dwt (penny weight)
GN (grain)
tl (tael (Hong Kong))
tl Upper right (tael (Singapore, Malaysia))
tl Right middle (tael (Taiwan))
mom (momme)
to (tola)
None
g (gram)
kg (kilogram)
ct (carat)
oz (ounce)
lb (pound)
ozt (troy ounce)
dwt (penny weight)
GN (grain)
tl (tael (Hong Kong))
tl Upper right (tael (Singapore, Malaysia))
tl Right middle (tael (Taiwan))
mom (momme)
to (tola)
Fine
Rough
Fine
Rough
Disabled
Enabled
(Outputting calibration
results)
(Measurement data in
compliance with GLP)
(Language for
printing)
Disabled
Enabled
Disabled
Enabled
English
Japanese (katakana)
Set tare range
Store tare
Buzzer control
Backlight control
“0” is displayed immediately after the key is pressed.
Reset the display to “0” when the balance is stabilized.
Disabled
Enabled
Off
On (Beeps when a value is confirmed, wrong operation is made, etc.)
Beeps when the key is pressed in addition to the beeping situations in 1.
(Buzzer tone)
* When “1” or ”2” is selected
in “ ”
Low
Middle
High
Off
On
On when the balance is powered by the AC adapter.
Off when powered by batteries.