52bweighing with addition function, 52b weighing with addition function, Reference – Rice Lake TS Series, Rice Lake Weighing Systems - Operation Manual User Manual
Page 45: Weighing with addition function

RL-TS Series Operation Manual 41
52B
Weighing with addition function
1
Place the first sample.
After an asterisk (*) is displayed, press the [Target] key.
The measured value is saved and a sigma [Σ] sign is displayed
for several seconds.
2
Place another sample (cumulative).
Place additional samples (net addition).
After an asterisk (*) is displayed, press the [Target] key.
The measured value is saved, and a [Σ] sign and the
cumulative weight are displayed for several seconds.
Repeat this operation to weigh all the samples to be summed.
After unloading the previous sample, check that the display
indicates “0,” and place the next sample.
Cumulating weight is also possible as follows: Press the
[Zero/Tare] key without unloading the balance and then place
next samples.
3
Display the cumulative weight.
Press the [Function] key twice.
A [Σ] sign and the cumulative weight are displayed.
- Pressing the [Zero/Tare] key when a cumulative weight is displayed clears the
cumulative weight.
- You can add samples when an asterisk (*) is displayed.
- When “t - Err” is displayed by pressing the [Target] key, it indicates that you put
additional samples on twice or that you unloaded some samples.
- The function setting “H. tA” can be used for turning ON/OFF the function to wait for
stabilization upon additions (Refer to “Appendix 1: Function Setting List” (P.
Reference
Reference