Digital outputs status digital outputs command, Status register – Rice Lake Signal Conditioning Transmitter/Indicators User Manual
Page 47

Operation 43
Digital Outputs Status
Digital Outputs Command
It allows control to the outputs status in EtHnEt mode (see Section 2.10 on page 27)
Bit a 1: output is closed; Bit a 0: output is open.
Setting bit 15 to 1 on the PLC, DeviceNet takes control of all the outputs, even if they are in different modes.
Status Register
Bit 0
OUTPUT 1 status
Bit 4
Bit 1
OUTPUT 2 status
Bit 5
Bit 2
OUTPUT 3 status
Bit 6
Bit 3
Bit 7
Bit 0
OUTPUT 1 status
Bit 8
Bit 1
OUTPUT 2 status
Bit 9
Bit 2
OUTPUT 3 status
Bit 10
Bit 3
Bit 11
Bit 4
Bit 12
Bit 5
Bit 13
Bit 6
Bit 14
Bit 7
Bit 15
Force Outputs
Bit 0
Cell Error
Bit 1
A/D Converter Malfunction
Bit 2
Maximum weight exceeded by 9 divisions
Bit 3
Gross weight higher than 110% of full scale
Bit 4
Gross weight beyond 999999 or less than -999999
Bit 5
Net weight beyond 999999 or less than -999999
Bit 6
Bit 7
Gross weight negative sign
Bit 8
Net weight negative sign
Bit 9
Peak weight negative sign
Bit 10
Net display mode
Bit 11
Weight stability
Bit 12
Weight within +/-¼ of a division around ZERO
Bit 13
Bit 14
Bit 15
Note