2.13 Reserved For The Installer
2.13.1Menu Locking
Through this procedure, it is possible to block the access to any menu on the instrument.
1. Press and hold
then press
to enter set-up menu.
2. Press
or
until menu to be locked is displayed.
3. Press
,
and
simultaneously for 3 seconds, the display shows C.ALIb (a decimal point appears
between the first and second letter that indicates this menu is now locked). If the operator tries to enter this
menu, access is denied and the display reads bLOC.
2.13.2Menu Unlocking
1. Press and hold
then press
to enter set-up menu.
2. Press
or
until menu to be un-locked is displayed.
3. Press
,
and
simultaneously for 3 seconds, the display shows CALIb (the decimal point between
the first and second letter is gone indicating the menu is un-locked).
2.13.3Temporary Menu Unlocking
1. Press and hold
then press
to enter set-up menu.
2. Press
or
until menu to be temporarily un-locked is displayed.
3. Press
and
simultaneously for 3 seconds, the display shows CALIb (the decimal point between the first
and second letter is gone indicating the menu is un-locked).
4. It is now possible to enter and modify all menus including those which are locked. By returning to the
weight display, the menu lock is restored.
2.13.4Default Scale
Operation must only be performed after contacting technical assistance
1. With power off, press and hold
, then power on. Display shows PrOG .
2. Press ,
bASE is displayed.
3. Press ,
PASSU is displayed.
4. Press ,
000000 is displayed.
5. Press
and
to enter 6935.
6. Press ,
UAIt is displayed.
7. Instrument will reboot.
By confirming the displayed program, the system variables are set to default values.