16 SCT Weight Transmitter Operator’s Manual
2.1.6 Setting Units of Measure
1. Press and hold
, then press
to enter set-up menu, CALIb will be displayed.
2. Press ,
FS-tEO is displayed.
3. Press
or
until unIt is displayed, press
.
4. Press
or
until desired unit is displayed, press
.
5. Press
twice to exit set-up menu.
* Indicates it is possible to set the display coefficient. To use COEFF it is necessary to enable it, closing the COEFF
input. See Section 2.1.7 on page 16.
If the print function is enabled, the symbol of the selected unit of measure will be printed after the measured
value.
2.1.7 Display Coefficient
By setting the coefficient the display is changed accordingly.
If one of the inputs is set to COEFF mode (see Section 2.10 on page 27) when the input is closed the value will be
displayed modified according to the coefficient; when the input is opened the standard weight display will be
restored.
1. Press and hold
, then press
to enter set-up menu, CALIb will be displayed.
2. Press ,
FS-tEO is displayed.
3. Press
or
until COEFF is displayed, press
.
4. Press
or
until desired number is displayed, press
.
5. Press
twice to exit set-up menu.
All other settings (setpoints, hysteresis, calibration ...) are expressed in weight value. If you want to
convert them to the new unit of measurement, perform one of the following procedures for changing the
system calibration.
The parameter must remain set to 1.0000.
HI LOG
kilograms
LI tre
litres*
G
grams
bAr
bar*
t
tons
AtN
atmospheres*
Lb
pounds*
PI ECE
pieces*
nEUton
newton*
nEU-N
newton metres*
LI tre
litres*
HI LO-N
kikgram metres*
bAr
bar*
OtHEr
units of measure not included*
HI LOG
kilograms
G
grams
t
tons
Lb
pounds
Value set in COEFF will be multiplied by the weight value currently displayed
nEUton
newton
Value set in COEFF will be multiplied by the weight value currently displayed
LI tre
litres
in COEFF set the specific weight in kg/l, assuming that the system is
calibrated in kg
bAr
bar
Value set in COEFF will be multiplied by the weight value currently displayed
AtN
atmospheres
Value set in COEFF will be multiplied by the weight value currently displayed
PI ECE
pieces
in COEFF set the weight of one piece
nEU-N
newton metres
Value set in COEFF will be multiplied by the weight value currently displayed
HI LO-N
kikgram metres
Value set in COEFF will be multiplied by the weight value currently displayed
OtHEr
other generic units of
measure not included in list
Value set in COEFF will be multiplied by the weight value currently displayed