9 serial communication settings – Rice Lake Signal Conditioning Transmitter/Indicators User Manual
Page 28

24 SCT Weight Transmitter Operator’s Manual
2.9
Serial Communication Settings
Figure 2-7. Serial Communications Menu Structure
Parameter
Choices
Description
rS-485
(Communication
Port)
nOnE *
Disables any type of communication.
NOdbuS
MODBUS-RTU protocol; possible addresses: from 1 to 99 (see Section
3.11)
ASCII
ASCII bidirectional protocol; possible addresses: from 1 to 99 (see
Section 3.12)
NOdU6-
NOd td
COntIn
Continuous weight transmission protocol (see Section 3.13), at the
frequency set in HERTZ parameter (from 10 to 300).
NOd t(set: PARITY=none, STOP=1)
NOd td(set: PARITY=none, STOP=1)
rI P
Continuous weight transmission protocol, streams net and gross (see
Section 3.14)
(set: BAUD=9600,PARITY=none, STOP=1)
Hdr1 P
Continuous weight transmission protocol, streams net and gross
including decimal. (see Section 3.14) (set: BAUD=9600,PARITY=none,
STOP=1)
Hdr1 PN
Continuous weight transmission protocol (see Section 3.14)
(set: BAUD=9600,PARITY=none, STOP=1)
When the remote display is set to gross weight:
- if the instrument displays the gross weight, the remote display shows
the gross weight.
- if the instrument shows the net weight the remote display shows the net
weight alternated with the message “net”
bAud
2400
4800
9600 *
1
9200
38400
115200
Transmission speed.
ADDR
1-99
1 *
Instruments address
rS485
nOnE
NodbUS
ASCII
Cont In
rI P
HdrI P
HdrI Pn
CALIb
FILtEr
PArA 0
SErIAL
tESt
Out-In
ANA LOG
Addr
bAud
HErt2
dELAY
PArItY
StOP
Enter #
9600
19200
38400
115200
4800
2400
30
40
50
60
20
10
100
200
300
80
70
Enter #
EUEn
Odd
nOnE
2
3
4
5
1
0
8
9
7
6