7 profibus – Rice Lake Signal Conditioning Transmitter/Indicators User Manual
Page 40

36 SCT Weight Transmitter Operator’s Manual
Digital Outputs Status
Digital Outputs Command
It allows to control the outputs status in dEUnEt mode (see Section 2.10 on page 27)
Bit a 1: output is closed; Bit a 0: output is open.
Setting bit 15 to 1 on the PLC, DeviceNet takes control of all the outputs, even if they are in different modes.
Status Register
3.7
Profibus
• The instrument works as a Profibus DP V0 slave in a Profibus DP network.
• Load the included gsd file (LAU_0C91.gsd) attached to the instrument in the development system of the
Profibus master.
• The available modules are:
- R = the register can be read only
- W = the register can be written only
- R/W = the register can be both read and written
Bit 0
OUTPUT 1 status
Bit 4
Bit 1
OUTPUT 2 status
Bit 5
Bit 2
OUTPUT 3 status
Bit 6
Bit 3
Bit 7
Bit 0
OUTPUT 1 status
Bit 8
Bit 1
OUTPUT 2 status
Bit 9
Bit 2
OUTPUT 3 status
Bit 10
Bit 3
Bit 11
Bit 4
Bit 12
Bit 5
Bit 13
Bit 6
Bit 14
Bit 7
Bit 15
Force Outputs
Bit 0
Cell Error
Bit 1
A/D Converter Malfunction
Bit 2
Maximum weight exceeded by 9 divisions
Bit 3
Gross weight higher than 110% of full scale
Bit 4
Gross weight beyond 999999 or less than -999999
Bit 5
Net weight beyond 999999 or less than -999999
Bit 6
Bit 7
Gross weight negative sign
Bit 8
Net weight negative sign
Bit 9
Peak weight negative sign
Bit 10
Net display mode
Bit 11
Weight stability
Bit 12
Weight within +/-¼ of a division around ZERO
Bit 13
Bit 14
Bit 15
Note