18 SCT Weight Transmitter Operator’s Manual
2.3
Zero Parameters
1. Press and hold
, then press
to enter set-up menu, CALIb will be displayed.
2. Press
or
until is displayed, press
.
3. Press
or
until desired parameter (see Table 5 ) is displayed, press
. The currently programmed
value is displayed.
4. Press
or
until desired value is displayed, press
.
5. Press
twice to exit set-up menu.
2.4
SCT20-DN (DeviceNet) Settings
1. Press and hold
and
to enter set-up menu. CALIb will be displayed.
2. Press
or
until dEUnEt is displayed, press
.
3. Press
or
until desired parameter is displayed, press
.
4. Press
or
until desired value is displayed, press
.
5. Press
twice to exit set-up menu.
Parameter
Choices
Description
0 SEt
Enter #
0-max full scale
300 *
Considered decimals:
300 – 30.0 – 3.00 –
0.300
Maximum zero range
Indicates the maximum weight value that can be zeroed off by external contact,
keypad or serial protocol
AutO 0
Enter #
0 - max 20% of full scale
0 *
Automatically zeroes the scale at power-on
If the weight value is lower than the value set in this parameter, the scale will zero
itself provided the weight does not exceed the value in the 0 SET parameter. To
disable this function set to 0.
trAC 0
nOnE *
1
-5
Zero tracking
Automatically zeroes the scale when within the range specified, as long as the
weight is within the 0 SET parameter and the scale is at standstill for at least one
second.
To disable this function
,
set to none
Example: if the parameter dI UI S is set to 5 and trAC 0 is set to 2, the weight
will be automatically set to zero for variations smaller than or equal to 10 (dI
UI S x trAC 0 ).
* - indicates default value.
Parameter
Choices
Description
Addr
1
-63
1 *
Set instrument address in the DeviceNet network.
bAud
6125H
6250H
6500H *
Set instrument address in the DeviceNet network.
* - indicates default value.
DeviceNet