61

AT8050

www.kontron.com

4.3.3.2

AMC Carrier Activation and Carrier Information Table

The AMC slot power budget is included in the following table.

Table 4-22:AMC Carrier Activation and Carrier Information Table

The Carrier Information Table gives the Carrier AMC.0 specification version and the Carrier's AMC sites list.

Link Type (Bits 19-12)

02h : PICMG 3.1 Ethernet Fabric Interface

Link Designator (Bits 11-0)

F42h : Fabric Interface, Channel 2, Port 0, 1, 2, 3

Link Descriptor

00002342h

Link Grouping ID (Bits 31-24)

0h : Single-Channel link

Link Type Extension (Bits 23-20)

0h : Fixed 1000Base-BX

Link Type (Bits 19-12)

02h : PICMG 3.1 Ethernet Fabric Interface

Link Designator (Bits 11-0)

342h : Fabric Interface, Channel 2, Port 0,1

Link Descriptor

00002142h

Link Grouping ID (Bits 31-24)

0h : Single-Channel link

Link Type Extension (Bits 23-20)

0h : Fixed 1000Base-BX

Link Type (Bits 19-12)

02h : PICMG 3.1 Ethernet Fabric Interface

Link Designator (Bits 11-0)

142h : Fabric Interface, Channel 2, Port 0

Link Descriptor

000F0181h

Link Grouping ID (Bits 31-24)

0h : Single-Channel link

Link Type Extension (Bits 23-20)

0h : None

Link Type (Bits 19-12)

F0h : OEM PCIe x4 + CLK Update Channel

Link Designator (Bits 11-0)

181h : Update Channel Interface 1, Port 0 ( all ten pairs )

Field

Value

Record Type ID

C0h

Record format version

02h

Record Length

*Calculated

Record Checksum

*Calculated

Header Checksum

*Calculated

Manufacturer ID

00315Ah

PICMG Record ID

17h

(Carrier Activation And Current Management)

Record Format Version

00h

Maximum Internal Current

29h (4.1 A @ 12 V ) => 49.2 Watts

Allowance for Module Activation Readiness

002h

Module Activation and Power Descriptor Count

01h

Carrier Activation and Power Descriptors.

7Ah, 22h, FFh

Local IPMB Address

7Ah

Maximum Module Current

29h (4.1 A @ 12 V ) => 49.2 Watts

Reserved

FFh

Field