Kontron AT8050 User Manual
Page 69
53
www.kontron.com
55
DIMM#4 SPD Pres
Discrete
DIMM#4 Temperature Sensor Presence Sensor type = 25h Entity Presence, Event
Reading type code = 6Fh Sensor specific, only offset 0,1 are used, -see IPMI v1.5
table 36.3, Sensor type code 25h (Entity Presence) for sensor definition
56
DIMM#5 SPD Pres
Discrete
DIMM#5 Temperature Sensor Presence Sensor type = 25h Entity Presence, Event
Reading type code = 6Fh Sensor specific, only offset 0,1 are used, -see IPMI v1.5
table 36.3, Sensor type code 25h (Entity Presence) for sensor definition
57
DIMM#6 SPD Pres
Discrete
DIMM#6 Temperature Sensor Presence Sensor type = 25h Entity Presence, Event
Reading type code = 6Fh Sensor specific, only offset 0,1 are used, -see IPMI v1.5
table 36.3, Sensor type code 25h (Entity Presence) for sensor definition
58
Fuse-Pres A Feed
Discrete
Fuse presence and fault detection -48 V on supply A Sensor type = 08h Power
Supply, Event Reading type code = 6Fh Sensor specific, only offset 0,1 are used,
-see IPMI v1.5 table 36.3, Sensor type code 08h for sensor definition
59
Fuse-Pres B Feed
Discrete
Fuse presence and fault detection -48 V on supply B Sensor type = 08h Power
Supply, Event Reading type code = 6Fh Sensor specific, only offset 0,1 are used,
-see IPMI v1.5 table 36.3, Sensor type code 08h for sensor definition
60
Fuse-RTN A Feed
Discrete
Fuse presence and fault detection RTN (Return) on supply A Sensor type = 08h
Power Supply, Event Reading type code = 6Fh Sensor specific, only offset 0,1 are
used, -see IPMI v1.5 table 36.3, Sensor type code 08h for sensor definition
61
Fuse-RTN B Feed
Discrete
Fuse presence and fault detection RTN (Return) on supply B Sensor type = 08h
Power Supply, Event Reading type code = 6Fh Sensor specific, only offset 0,1 are
used, -see IPMI v1.5 table 36.3, Sensor type code 08h for sensor definition
62
Fuse-Earl A Feed
Discrete
Fuse presence and fault detection on Early -48V supply A Sensor type = 08h
Power Supply, Event Reading type code = 6Fh Sensor specific, only offset 0,1 are
used, -see IPMI v1.5 table 36.3, Sensor type code 08h for sensor definition
63
Fuse-Earl B Feed
Discrete
Fuse presence and fault detection on Early -48V supply B Sensor type = 08h
Power Supply, Event Reading type code = 6Fh Sensor specific, only offset 0,1 are
used, -see IPMI v1.5 table 36.3, Sensor type code 08h for sensor definition
64
Power State
Discrete
Board Power State Sensor type = D0h Kontron OEM Power State Sensor Event
Reading type code = 6Fh Sensor specific -see OEM sensor table, Sensor type
code D1h for sensor definition
65
Power Good
Discrete
Actual power good status Sensor type = 08h Power Supply Event Reading type
code = 77h OEM -see OEM sensor table, Event/Reading type code 77h for sensor
definition
66
Power Good Event
Discrete
Power good status event that occur since the last power on or reset. Sensor type
= 08h Power Supply Event Reading type code = 77h OEM -see OEM sensor table,
Event/Reading type code 77h for sensor definition
67
Board Reset
Discrete
Board reset type and sources Sensor type = CFh OEM (Kontron Reset Sensor),
Event Reading type code = 03h Digital Discrete offset 0,1 are used, -see OEM
sensor table, Sensor type code CFh for sensor definition
68
POST Value
Discrete
Show current postcode value. No event generated by this sensor. Sensor type =
C6h OEM (Kontron POST value sensor), Event Reading type code = 6Fh Sensor
specific, offset 0 to 7 and 14 are used, -see OEM sensor table, Sensor type code
C6h for sensor definition
69
Boot Error
Discrete
Boot Error Sensor Type = 1Eh Boot Error
Reading type code = 6Fh Sensor Specific, only offset 0 is used, -see IPMI v1.5
table 36.3, Sensor type code 1Eh for sensor definition
70
POST Error
Discrete
CPU Power On Self Test Error Sensor type = 0Fh System Firmware Progress Event
Reading type code = 6Fh Sensor specific, only offset 0 is used, -see IPMI v1.5
table 36.3, Sensor type code 0Fh (System Firmware Progress) for sensor
definition
71
Critical Int
Discrete
Critical Interrupt Sensor type = 13h Critical Interrupt, Event Reading type code
= 6Fh Critical Interrupt offset 0,4,5 are used, -see IPMI v1.5 table 36.3, Sensor
type code 13h for sensor definition
ID
Sensor Name
Sensor Class
Description (Sensor Type, Event trigger)