beautypg.com

2 ipmc health indicator sensor aggregation – Kontron AT8050 User Manual

Page 72

background image

56

AT8050

www.kontron.com

4.3.2.2

IPMC Health Indicator Sensor Aggregation

The following table shows the sensors involved in the health sensor aggregation.

Table 4-18: IPMC Health Indicator Sensor Aggregation Table

100

ME Availability

Discrete

Provides status on the chipset Management Engine

Sensor type = 28h Management Subsystem Health

Event Reading type code = 0Ah Generic Discrete, offset 2,6,8 are used

see IPMI v1.5 table 36.2, event reading type code 0Ah for sensor definition

101

Jumper Status

Discrete

Reflects on-board jumper presence

Sensor type = D3h OEM (Kontron OEM Jumper Status)

Event Reading type code = 6Fh Sensor specific, offsets 0 to 14 are used

-see OEM table, Sensor type code D3h (Kontron OEM Jumper Status) for sensor

definition

102

IPMI Info-1

Discrete

Internal Management Controller firmware diagnostic Sensor type = C0h Kontron

OEM Firmware Info Event Reading type code = 70h Kontron OEM Internal

Diagnostic -see OEM table, Sensor type code C0h (Kontron OEM Firmware Info)

for sensor definition and Event/Reading type code 70h (ontron OEM Internal

Diagnostic)

103

IPMI Info-2

Discrete

Internal Management Controller firmware diagnostic Sensor type = C0h Kontron

OEM Firmware Info Event Reading type code = 75h Kontron OEM Internal

Diagnostic -see OEM table, Sensor type code C0h (Kontron OEM Firmware Info)

for sensor definition and Event/Reading type code 70h (ontron OEM Internal

Diagnostic)

IPMI sensor ID

Sensor Name

5

Temp -48V A Feed

6

Temp -48V B Feed

7

Temp Mez 12V Out

8

Temp VDDQ

9

Temp Vcore

10

Temp IPMC

11

Temp IOH

12

Temp ICH

13

Temp Mngt Lan

14

Temp BI Lan

15

Temp FI Lan

16

Temp Bay Inlet

17

Temp CPU

18

Temp DIMM#1

19

Temp DIMM#2

20

Temp DIMM#3

21

Temp DIMM#4

22

Temp DIMM#5

23

Temp DIMM#6

25

Brd Input Power

ID

Sensor Name

Sensor Class

Description (Sensor Type, Event trigger)