beautypg.com

Kontron AT8050 User Manual

Page 67

background image

51

AT8050

www.kontron.com

26

AMC Power

Threshold

FRU 1 (AMC B1) Power consumption in watts

Sensor type = 0Bh Other Unit-Based Sensor (Watt)

Event Reading type code = 01h threshold base

see IPMI v1.5 section 29.13.3 for threshold based event

27

RTM Power

Threshold

FRU 2 (RTM) + FRU 3 (RTM's disk) Power consumption in watts

Sensor type = 0Bh Other Unit-Based Sensor (Watt)

Event Reading type code = 01h threshold base

see IPMI v1.5 section 29.13.3 for threshold based event

28

Vcore Power

Threshold

Vcore Power consumption in watts

Sensor type = 0Bh Other Unit-Based Sensor (Watt)

Event Reading type code = 01h threshold based

see IPMI v1.5 section 29.13.3 for threshold based event

29

Vddq Power

Threshold

Vddq Power consumption in watts

Sensor type = 0Bh Other Unit-Based Sensor (Watt)

Event Reading type code = 01h threshold based

see IPMI v1.5 section 29.13.3 for threshold based event

30

Vcc Mez Hold-UP

Threshold

Voltage on power mezsanine Vcc Hold-UP Sensor type = 02h voltage Event

Reading type code = 01h threshold based see IPMI v1.5 section 29.13.3 for

threshold based event

31

Vcc +1.0V SUS

Threshold

Voltage on board 1.0V suspend (management) power supply

Sensor type = 02h voltage

Event Reading type code = 01h threshold based

see IPMI v1.5 section 29.13.3 for threshold based event

32

Vcc +1.2V SUS

Threshold

Voltage on board 1.2V suspend (management) power supply (Volts)

Sensor type = 02h voltage

Event Reading type code = 01h threshold based

see IPMI v1.5 section 29.13.3 for threshold based event

33

Vcc +1.8V SUS

Threshold

Voltage on board 1.8V suspend (management) power supply (Volts)

Sensor type = 02h voltage

Event Reading type code = 01h threshold based

see IPMI v1.5 section 29.13.3 for threshold based event

34

Vcc +3.3V SUS

Threshold

Voltage on board 3.3V suspend (management) power supply (Volts)

Sensor type = 02h voltage

Event Reading type code = 01h threshold based

see IPMI v1.5 section 29.13.3 for threshold based event

35

Vcc +5V SUS

Threshold

Voltage on board 5V suspend (management) power supply (Volts)

Sensor type = 02h voltage

Event Reading type code = 01h threshold based

see IPMI v1.5 section 29.13.3 for threshold based event

36

Vcc +12V SUS

Threshold

Voltage on board 12V suspend (management) power supply (Volts)

Sensor type = 02h voltage

Event Reading type code = 01h threshold based

see IPMI v1.5 section 29.13.3 for threshold based event

37

Vcc Vtt

Threshold

Voltage on board Vtt payload power supply (Volts)

Sensor type = 02h voltage

Event Reading type code = 01h threshold based

see IPMI v1.5 section 29.13.3 for threshold based event

38

Vcc VttDdr

Threshold

Voltage on board Vtt Ddr payload power supply (Volts)

Sensor type = 02h voltage

Event Reading type code = 01h threshold based

see IPMI v1.5 section 29.13.3 for threshold based event

39

Vcc Vcore

Threshold

Voltage on board Vcore payload power supply (Volts)

Sensor type = 02h voltage

Event Reading type code = 01h threshold based

see IPMI v1.5 section 29.13.3 for threshold based event

ID

Sensor Name

Sensor Class