Kontron AT8050 User Manual
Page 67
51
www.kontron.com
26
AMC Power
Threshold
FRU 1 (AMC B1) Power consumption in watts
Sensor type = 0Bh Other Unit-Based Sensor (Watt)
Event Reading type code = 01h threshold base
see IPMI v1.5 section 29.13.3 for threshold based event
27
RTM Power
Threshold
FRU 2 (RTM) + FRU 3 (RTM's disk) Power consumption in watts
Sensor type = 0Bh Other Unit-Based Sensor (Watt)
Event Reading type code = 01h threshold base
see IPMI v1.5 section 29.13.3 for threshold based event
28
Vcore Power
Threshold
Vcore Power consumption in watts
Sensor type = 0Bh Other Unit-Based Sensor (Watt)
Event Reading type code = 01h threshold based
see IPMI v1.5 section 29.13.3 for threshold based event
29
Vddq Power
Threshold
Vddq Power consumption in watts
Sensor type = 0Bh Other Unit-Based Sensor (Watt)
Event Reading type code = 01h threshold based
see IPMI v1.5 section 29.13.3 for threshold based event
30
Vcc Mez Hold-UP
Threshold
Voltage on power mezsanine Vcc Hold-UP Sensor type = 02h voltage Event
Reading type code = 01h threshold based see IPMI v1.5 section 29.13.3 for
threshold based event
31
Vcc +1.0V SUS
Threshold
Voltage on board 1.0V suspend (management) power supply
Sensor type = 02h voltage
Event Reading type code = 01h threshold based
see IPMI v1.5 section 29.13.3 for threshold based event
32
Vcc +1.2V SUS
Threshold
Voltage on board 1.2V suspend (management) power supply (Volts)
Sensor type = 02h voltage
Event Reading type code = 01h threshold based
see IPMI v1.5 section 29.13.3 for threshold based event
33
Vcc +1.8V SUS
Threshold
Voltage on board 1.8V suspend (management) power supply (Volts)
Sensor type = 02h voltage
Event Reading type code = 01h threshold based
see IPMI v1.5 section 29.13.3 for threshold based event
34
Vcc +3.3V SUS
Threshold
Voltage on board 3.3V suspend (management) power supply (Volts)
Sensor type = 02h voltage
Event Reading type code = 01h threshold based
see IPMI v1.5 section 29.13.3 for threshold based event
35
Vcc +5V SUS
Threshold
Voltage on board 5V suspend (management) power supply (Volts)
Sensor type = 02h voltage
Event Reading type code = 01h threshold based
see IPMI v1.5 section 29.13.3 for threshold based event
36
Vcc +12V SUS
Threshold
Voltage on board 12V suspend (management) power supply (Volts)
Sensor type = 02h voltage
Event Reading type code = 01h threshold based
see IPMI v1.5 section 29.13.3 for threshold based event
37
Vcc Vtt
Threshold
Voltage on board Vtt payload power supply (Volts)
Sensor type = 02h voltage
Event Reading type code = 01h threshold based
see IPMI v1.5 section 29.13.3 for threshold based event
38
Vcc VttDdr
Threshold
Voltage on board Vtt Ddr payload power supply (Volts)
Sensor type = 02h voltage
Event Reading type code = 01h threshold based
see IPMI v1.5 section 29.13.3 for threshold based event
39
Vcc Vcore
Threshold
Voltage on board Vcore payload power supply (Volts)
Sensor type = 02h voltage
Event Reading type code = 01h threshold based
see IPMI v1.5 section 29.13.3 for threshold based event
ID
Sensor Name
Sensor Class
Description (Sensor Type, Event trigger)