beautypg.com

Kontron AT8050 User Manual

Page 71

background image

55

AT8050

www.kontron.com

87

FRU Over Icc

Discrete

FRU Over Current Sensor Sensor type = CBh OEM (Kontron OEM FRU Over Current)

Event Reading type code = 03h Digital Discrete offset 0,1 are used, -see OEM

table, Sensor type code CBh (Kontron OEM FRU Overcurrent) for sensor

definition

88

FRU Sensor Error

Discrete

FRU Error during external FRU Sensor discovery Sensor type = CCh OEM (Kontron

OEM FRU sensor error) Event Reading type code = 03h Digital Discrete offset 0,1

are used, -see OEM table, Sensor type code CCh (Kontron OEM FRU sensor error)

for sensor definition

89

FRU Pwr Denied

Discrete

FRU Power Denial Detection Sensor type = CDh OEM (Kontron FRU Power denied)

Event Reading type code = 03h Digital Discrete offset 0,1 are used -see OEM

table, Sensor type code CDh (Kontron OEM FRU Power Denied) for sensor

definition

90

FRU MngtPwr Fail

Discrete

FRU Management Power Fail Sensor type = D2h OEM (Kontron FRU Management

Power Fail) Event Reading type code = 03h Digital Discrete offset 0,1 are used -

see OEM table, Sensor type code D2h (Kontron OEM FRU Management Power

Fail) for sensor definition

91

FRU0 Agent

Discrete

FRU Information Agent - FRU0 Data Error Detection Sensor type = C5h OEM

(Kontron FRU Info Agent) Event Reading type code = 0Ah Generic Discrete,

offset 6,8 are used -see OEM table, Sensor type code C5h (Kontron OEM FRU

Information Agent) for sensor definition

92

FRU1 Agent

Discrete

FRU Information Agent - FRU1 Data Error Detection Sensor type = C5h OEM

(Kontron FRU Info Agent), Event Reading type code = 0Ah Generic Discrete,

offset 6,8 are used -see OEM table, Sensor type code C5h (Kontron OEM FRU

Information Agent) for sensor definition

93

FRU2 Agent

Discrete

FRU Information Agent - FRU2 Data Error Detection Sensor type = C5h OEM

(Kontron FRU Info Agent), Event Reading type code = 0Ah Generic Discrete,

offset 6,8 are used -see OEM table, Sensor type code C5h (Kontron OEM FRU

Information Agent) for sensor definition

94

FRU3 Agent

Discrete

FRU Information Agent - FRU3 Data Error Detection Sensor type = C5h OEM

(Kontron FRU Info Agent), Event Reading type code = 0Ah Generic Discrete,

offset 6,8 are used -see OEM table, Sensor type code C5h (Kontron OEM FRU

Information Agent) for sensor definition

95

EventRcv ComLost

Discrete

Detects communication with the event receiver (ShMc) has been lost Sensor

type = 1Bh Cable/Interconnect, Event Reading type code = 03h Digital Discrete -

see IPMI v1.5 table 36.2 and table 36.3 for sensor definition

96

IPMC Reboot

Discrete

IPMC reboot detection Sensor type = 24h Platform Alert, Event Reading type

code = 03h Digital Discrete offset 0,1 are used -see IPMI v1.5 table 36.3, Sensor

type code 24h for sensor definition

97

IPMC FwUp

Discrete

Kontron OEM IPMC firmware upgrade Status Sensor type = C7h OEM (Kontron

OEM MC firmware upgrade Status) Event Reading type code = 6Fh Sensor

specific, offset 0,1 are used -see OEM table, Sensor type code C7h (Kontron OEM

MC firmware upgrade Status) for sensor definition

98

IPMC Storage Err

Discrete

Management sub-system health: non volatile memory error. Sensor type = 28h

Management Subsystem Health Event Reading type code = 6Fh Sensor specific,

only offset 1 is used, -see IPMI v1.5 table 36.3, Sensor type code 28h for sensor

definition

99

IPMC SEL State

Discrete

Specify if the status of the SEL (Cleared/Almost Full/Full) Sensor type = 10h

Event Logging Disable Event Reading type code = 6Fh Sensor specific, only

offset 2,4,5 are used, -see IPMI v1.5 table 36.3, Sensor type code 10h (Event

Log Disable) for sensor definition

ID

Sensor Name

Sensor Class

Description (Sensor Type, Event trigger)