55
www.kontron.com
87
FRU Over Icc
Discrete
FRU Over Current Sensor Sensor type = CBh OEM (Kontron OEM FRU Over Current)
Event Reading type code = 03h Digital Discrete offset 0,1 are used, -see OEM
table, Sensor type code CBh (Kontron OEM FRU Overcurrent) for sensor
definition
88
FRU Sensor Error
Discrete
FRU Error during external FRU Sensor discovery Sensor type = CCh OEM (Kontron
OEM FRU sensor error) Event Reading type code = 03h Digital Discrete offset 0,1
are used, -see OEM table, Sensor type code CCh (Kontron OEM FRU sensor error)
for sensor definition
89
FRU Pwr Denied
Discrete
FRU Power Denial Detection Sensor type = CDh OEM (Kontron FRU Power denied)
Event Reading type code = 03h Digital Discrete offset 0,1 are used -see OEM
table, Sensor type code CDh (Kontron OEM FRU Power Denied) for sensor
definition
90
FRU MngtPwr Fail
Discrete
FRU Management Power Fail Sensor type = D2h OEM (Kontron FRU Management
Power Fail) Event Reading type code = 03h Digital Discrete offset 0,1 are used -
see OEM table, Sensor type code D2h (Kontron OEM FRU Management Power
Fail) for sensor definition
91
FRU0 Agent
Discrete
FRU Information Agent - FRU0 Data Error Detection Sensor type = C5h OEM
(Kontron FRU Info Agent) Event Reading type code = 0Ah Generic Discrete,
offset 6,8 are used -see OEM table, Sensor type code C5h (Kontron OEM FRU
Information Agent) for sensor definition
92
FRU1 Agent
Discrete
FRU Information Agent - FRU1 Data Error Detection Sensor type = C5h OEM
(Kontron FRU Info Agent), Event Reading type code = 0Ah Generic Discrete,
offset 6,8 are used -see OEM table, Sensor type code C5h (Kontron OEM FRU
Information Agent) for sensor definition
93
FRU2 Agent
Discrete
FRU Information Agent - FRU2 Data Error Detection Sensor type = C5h OEM
(Kontron FRU Info Agent), Event Reading type code = 0Ah Generic Discrete,
offset 6,8 are used -see OEM table, Sensor type code C5h (Kontron OEM FRU
Information Agent) for sensor definition
94
FRU3 Agent
Discrete
FRU Information Agent - FRU3 Data Error Detection Sensor type = C5h OEM
(Kontron FRU Info Agent), Event Reading type code = 0Ah Generic Discrete,
offset 6,8 are used -see OEM table, Sensor type code C5h (Kontron OEM FRU
Information Agent) for sensor definition
95
EventRcv ComLost
Discrete
Detects communication with the event receiver (ShMc) has been lost Sensor
type = 1Bh Cable/Interconnect, Event Reading type code = 03h Digital Discrete -
see IPMI v1.5 table 36.2 and table 36.3 for sensor definition
96
IPMC Reboot
Discrete
IPMC reboot detection Sensor type = 24h Platform Alert, Event Reading type
code = 03h Digital Discrete offset 0,1 are used -see IPMI v1.5 table 36.3, Sensor
type code 24h for sensor definition
97
IPMC FwUp
Discrete
Kontron OEM IPMC firmware upgrade Status Sensor type = C7h OEM (Kontron
OEM MC firmware upgrade Status) Event Reading type code = 6Fh Sensor
specific, offset 0,1 are used -see OEM table, Sensor type code C7h (Kontron OEM
MC firmware upgrade Status) for sensor definition
98
IPMC Storage Err
Discrete
Management sub-system health: non volatile memory error. Sensor type = 28h
Management Subsystem Health Event Reading type code = 6Fh Sensor specific,
only offset 1 is used, -see IPMI v1.5 table 36.3, Sensor type code 28h for sensor
definition
99
IPMC SEL State
Discrete
Specify if the status of the SEL (Cleared/Almost Full/Full) Sensor type = 10h
Event Logging Disable Event Reading type code = 6Fh Sensor specific, only
offset 2,4,5 are used, -see IPMI v1.5 table 36.3, Sensor type code 10h (Event
Log Disable) for sensor definition
ID
Sensor Name
Sensor Class
Description (Sensor Type, Event trigger)