Power adjustment – Dynojet 250i: Installation Guide User Manual
Page 158
Model 200i and 250i Motorcycle Dynamometer Installation Guide
A P P E N D I X C
Power Adjustment
C-2
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
POWER ADJUSTMENT
The 240 VAC theta controller is calibrated for a nominal 230 to 240 VAC line voltage;
in certain countries, line voltages of 210 to 220 VAC may be encountered and the dip
switch can be set to provide full output current of 10 amps even with the reduced line
voltage.
Note: This controller cannot be converted to operate on 120 VAC line voltage.
Hazardous voltage. To avoid risk of electrical shock, disconnect the power cord
to the theta controller. Do not remove the cover. No user serviceable parts
inside.
A
CCESSING
THE
D
IP
S
WITCHES
Dynojet recommends you set the dip switches at the time of installation.
The two dip switches are the only adjustments that can be altered. Be sure not
to damage any other parts on the circuit board. Do not attempt any other
adjustments.
1
Remove the metal plug from the bottom of the theta controller.
2
Use a small screwdriver to set the dip switches for the desired line voltage.
3
Replace the metal plug.
Figure C-1: Theta Controller Metal Plug
metal plug