beautypg.com

Dynojet 250i: Installation Guide User Manual

Page 136

background image

Model 200i and 250i Motorcycle Dynamometer Installation Guide

C H A P T E R 5
Connecting the RPM Pickup

5-8

Erratic tachometer operation can be caused by Electro Magnetic Interference (EMI).
The following are some steps that the user can take to clean up the signal if an EMI
situation occurs.

• Ground the computer case to a good earth ground, like the receptacle box.
• Keep the computer as far away from the dyno as possible.
• Try attaching one secondary inductive cable to one wire and attach a second

inductive cable to the first in a piggy back fashion. The first inductive cable acts as a

filter.

• Using a jumper wire, ground the metal case of the inductive clip to the motorcycle

chassis.

• Rout the inductive wire(s) 90 degrees (perpendicular) away from the motorcycle.

When laid alongside (parallel) to the motorcycle they can act as an antenna.

This manual is related to the following products: