Arc Machines 207 User Manual
Page 47

MODEL 207A AND 207A-1
OPERATION MANUAL
Doc. No. 740044
Rev F
SECTION V - OPERATION
5.8
AUTO ROTATION CALIBRATION
2. (continued)
AUTO TRAVEL SPEED CALIBRATION
WELD HEAD SELECTION MENU
SELECT MAX. RPM (STAMPED ON HEAD TAG)
20.0 2.0 OTHER MANUAL
Read the Serial Number Tag on the Weld Head and note the MAX RPM
rating (a M9-500 is 20 RPM).
3. Use the F key under either 20.0, 2.0 or OTHER (anything in between) (note
that the choice not blinking is the current one selected) and the following
screen will be displayed:
CHECK THAT THE HEAD IS SAFE TO ROTATE
PRESS ENTER TO START CALIBRATION
USE C KEY TO RETURN TO SET UP SCREEN
4. When the ENTER key is pressed the M-207A will proceed to move the rotor
automatically and calibrate it. MAKE SURE IT IS SAFE TO ROTATE
BEFORE STARTING.
5. When calibration is complete the lower display will appear as follows:
USE C KEY TO RETURN TO SET UP SCREEN
CALIBRATION COMPLETE
6. If the system cannot rotate the head or complete the calibration for some
reason (like the head is not connected or it is jammed) the following will
appear:
UNABLE TO CALIBRATE WELD HEAD
Check again that the head is properly connected and free to rotate.
5.12