SECTION V - OPERATION
5.0
INTRODUCTION
Operation covers those steps that must be taken to actually perform a weld.
Programming and development of schedules are not covered in this section.
It is very important to insure before operating, that the operator has INSTALLED
the M-207A per section III and has a good understanding of functions from
section IV. Function explanations are not covered in this section.
The M-207A uses two displays to provide information and instructions for use.
For the most part, the information and instructions presented on these displays are
adequate explanation of operation. This section is only intended as a guideline to
get started with, for first-time users, AFTER HAVING ATTENDED AN AMI
M-207A TRAINING CLASS.
5.1
INITIAL POWER ON/STATUS SCREEN
1. Before connecting or energizing the AC power; verify that all input power set
up requirements of step 3.1 have been complied with.
WARNING
Applying the wrong input AC voltage to an M-207A (for how it is set up)
CAN CAUSE THE INPUT VARISTORS TO FAIL. Before turning the
power ON MAKE SURE THE INPUT POWER SET UP IS CORRECT
FOR THE POWER BEING USED.
2. The M-207A can be turned on without the adapter cable, gas hoses or weld
head connected. However, to verify proper operation they must be connected.
Insure that all of these connections are made per steps 3.2, 3.3 and 3.4.
3. Plug in the AC power cable to the AC source. Move the circuit breaker (CB1)
to the ON position.
4. After a few seconds the STATUS SCREEN will appear as shown on the next
page:
5.1