beautypg.com

Arc Machines 207 User Manual

Page 30

background image

MODEL 207A AND 207A-1

OPERATION MANUAL

Doc. No. 740044
Rev F

SECTION IV - SYSTEM FUNCTIONS

4.4

PANEL KEYS


21. WELD/TEST KEY - At power on the M-207A will always be in the TEST

mode. In TEST mode a weld sequence can be run but NO ARC will be

struck. The user must press this key to initiate WELD mode. Once this is

done the M-207A will stay in WELD mode as long as the same weld

schedule is displayed. Changing schedules will cause the system to return to

the TEST mode.


22. STOP PRINT KEY - This key will allow the user to stop the printing

process for any reason.

23. PAPER FEED KEY - This key allows the user to advance the paper in the

printer.


4.5

OPERATE MODE SWITCH


This is a three position switch with a locking key. When set to the desired

position (mode) the key can be removed to prevent any non-key holder from

changing the mode.


The OPERATE MODE SWITCH sets the M-207A to be run in any of three

separate modes as described below:


1. OPERATE/WELD SELECT POSITION - The OPERATE mode is for

standard welding operations. It allows access to all weld schedules and set-

up screens. All normal system operations, such as weld sequence, etc. are

performed in this mode. In this mode the operator CANNOT perform any

PROGRAMMING functions or changes to the memory such as creating,

modifying, transferring or deleting.


2. MODE LOCK - After a weld schedule has been selected it may be locked-in

to prevent selection of any other weld schedule. This feature is intended

primarily for when the operator is welding out-of-sight of the M-207A or if a

supervisor wishes to insure that ONLY a particular weld schedule is used.


3. PROGRAM/OPERATE - In order to CREATE, MODIFY, TRANSFER,

COPY or DELETE a weld schedule in the system memory, the mode switch

must be set to this position. All system operations, such as weld sequence,

can also be performed in this mode.




4.11