MODEL 207A AND 207A-1
OPERATION MANUAL
Doc. No. 740044
Rev F
SECTION V - OPERATION
5.2
USE OF NEXT/PREV SCREENS/LEVELS (continued)
The weld schedule can be programmed to have up to a 100 levels of screen 2 and
3. When viewing screen 2 or 3 the operator can press the NEXT LEVEL key to
view the values for the next level (if programmed). When displaying level 2 or
greater, pressing the PRE LEVEL key will then display the previous level.
Pressing the NEXT SCREEN or PREV SCREEN key after using the NEXT
LEVEL or PREV LEVEL key will display the next screen for that level, except if
the next screen is screen 1 or 4 above, these screens are the same for all levels.
Reference figure 7 for a flow chart on the use of NEXT/PREV SCREEN and
LEVEL keys.
5.3
WELD SCHEDULE SELECTION
The following describes how to select a weld schedule from the library. The
OPERATE MODE switch must be in the OPERATE or PROGRAM position. Be
sure to have read section 5.2, use of NEXT/PREV keys before proceeding.
1. Press the C key until the STATUS screen appears.
2. Press the LIB key and the following display will appear:
USE SCREEN KEYS TO FIND # PRESS ENTER
OR IF # IS KNOWN ENTER #--- PRESS ENTER
# OD WALL TYPE MAT QTY *
001 1.500 .065 TUBE SS 0010*
Instructions are displayed on the upper screen. The first weld schedule in
memory (may not be #001) will be displayed on the lower screen.
3. If you know what weld schedule you want, enter its number using the numeric
keys. The numbers will appear in the --- area as you enter them. If you make
a mistake press CE and start over. When you have entered and verified the
correct number press the ENTER key. After a few seconds your selected weld
schedule will appear on the display. Proceed to step 5 (below).
5.4