Arc Machines 207 User Manual
Page 16

MODEL 207A AND 207A-1
OPERATION MANUAL
Doc. No. 740044
Rev F
SECTION II - SPECIFICATIONS
2.3
MULTI-LEVEL FUNCTIONS (continued)
FUNCTION POSSIBLE CHANGES
PRIMARY CURRENT.............................................. = 1 to 99 levels
BACKGROUND CURRENT.................................... = 1 to 99 levels
PRIMARY PULSE TIME.......................................... = 1 to 99 levels
BACKGROUND PULSE TIME................................ = 1 to 99 levels
PULSE MODE (ON/OFF)......................................... = 1 to 99 levels
PRIMARY ROTATION ............................................ = 1 to 99 levels
BACKGROUND ROTATION RPM......................... = 1 to 99 levels
ROTATION MODE (CONT/STEP/OFF) ................. = 1 to 99 levels
2.4
AMBIENT TEMPERATURE RANGE - 32 F (0 C) to 110 F (45 C).
2.5
CABLE OPERATING DISTANCE LIMITS - Standard = 25’ (7.6 m)
Maximum = 100’ (30.5 m)
The standard distance consists of a 15’ adapter cable and a 10’ weld head cable
combined together. The maximum distance is achieved by adding extension
cables to the standard cables.
The above are considered normal limits. With special options, distances of 500
feet or more can be achieved. Consult an AMI representative for more
information.
2.4