1
Trouble check
I
Picture
-
Symptom
Cause and/or corrective actions
The picture appears a little later on
the LCD screen or in the viewfinder
when you set the POWER switch to
CAMERA.
• The camcorder is not malfunctioning.
A display such as "C:OD:DQ"
appears on the LCD screen or in the
viewfinder.
• The self-diagnosis display function has activated.
Check the code and diagnosis the problem by refering to
the code chart, (p. 91)
others
Symptom
Cause and/or corrective actions
While editing using the DV
connecting cable, recording picture
cannot be monitored.
• Remove the DV connecting cable, and connect it again.
The camcorder becomes warm.
• If the power of the cammcorder is on for a long time, it
becomes warm, which is not malfunction.
The supplied Remote Commander
does not work.
• COMMANDER is set to OFF in the menu system.
-> Set it to ON. (p. 25)
• Something is blocking the infrared rays.
Remove the obstacle.
• The battery is not inserted with the correct polarity.
-> Insert the battery with the correct polarity, (p. 99)
• The batteries are dead.
■> Insert new ones. (p. 99)
No function works though the power
is on.
• Disconnect the battery pack or the connecting plate of the AC
power adaptor, then reconnect it after about 1 minute. Turn
the power on. If the functions still do not work, press the
RESET button at the upper right from the START/STOP
MODE switch using a sharp-pointed object. (If you press the
RESET button, all the settings including the date and time
return to the default.) (p. 96)
AC P9 >y)ffsir adapjtor
Symptom •
Corrective actions
The VTR/CAMERA or CHARGE
lamp does not light.
• Disconnect the power cord. After about 1 minute, reconnect
the power cord. (p. 7)
The CHARGE lamp flashes.
• See the chart on the next page.
Continued to the next page