beautypg.com

Returning the autoloader for service – Dell PowerVault 124T User Manual

Page 63

background image

0000000000000100

Drive TAflag[57]

Automation Interface

Failure

TapeAlert Log Entry:

0000000000000080

The tape drive has a problem

with the automation interface.

The drive has

identified an interface

fault.

Check the power to the

automation system.

Check the cables and

cable connections.

Drive TAflag[58]

Firmware Failure

TapeAlert Log Entry:

0000000000000040

The tape drive has reset itself

due to a detected firmware fault.

Firmware issue

encountered.

Not supported.

Drive TAflag[59]

WORM Medium -

Integrity Check

Failed

TapeAlert Log Entry:

0000000000000020

The tape drive has detected an

inconsistency during the WORM

medium integrity checks.

WORM cartridge may

have been tampered

with.

Replace WORM medium.

Drive TAflag[60]

WORM Medium -

Overwrite Attempted

TapeAlert Log Entry:

0000000000000010

An attempt had been made to

overwrite user data on WORM

medium.

The application

software does not

recognize the medium

as WORM.

If a WORM medium was

used inadvertently,

replace it with a normal

data medium.

If a WORM medium was

used intentionally:

- check that the

software application is

compatible with the

WORM medium format

you are using.

- check that the

medium is bar-coded

correctly for WORM.

Returning the Autoloader for Service

If you need to return the autoloader or a component of the autoloader for service, see

Contacting Dell

. The

following steps will help you to prepare the autoloader for shipment, remove the autoloader from a rack, and

package the autoloader.

To prepare the autoloader for shipment

1. Remove all cartridges from the unit.

2. Power off the autoloader through the front panel.

3. Remove the power, Ethernet, and SAS cables from the autoloader.

NOTE: Do not ship these items if you are returning the autoloader.