Dell PowerVault 124T User Manual
Page 48

61
Drive Login Error
Check the TapeAlert log for more specific drive error information.
Refer to
Table 3
for recommended actions.
Power cycle the autoloader using the front panel power button
and retry the operation.
If all previous steps fail, see
Contacting Dell
.
62
Drive Logout/Unexpected
Error
63
Drive Command Failed
64
Drive Response Timeout
65
Command Flushed From
Queue
66
Drive Manager Not In
Correct State
67
Drive Reporting Not Ready
68
Autoclean Move Failed
Check the Remote Management Unit autoclean Configuration
settings. Ensure that a valid cleaning cartridge is located at the
configured location.
Verify that the cleaning cartridge does not have labels or other
matter placed anywhere on the cartridge except where labels are
expected to be placed.
Try a different cleaning cartridge.
If the operation fails with two different cleaning cartridges, see
Contacting Dell
.
69
Drive Unload Retry
Check the TapeAlert log for more specific drive error information.
Refer to
Table 3
for recommended actions.
Verify that the cleaning cartridge does not have labels or other
matter placed anywhere on the cartridge except where labels are
expected to be placed.
Try to load a different piece of media.
Power cycle the autoloader using the front panel power button
and retry the operation.
If all previous steps fail, see
Contacting Dell
.
6D
Drive Communications
Error
Check the TapeAlert log for more specific drive error information.
Refer to
Table 3
for recommended actions.
Power cycle the autoloader using the front panel power button
and retry the operation.
If all previous steps fail, see
Contacting Dell
.
6E
Drive Communications
Error
6F
Loader Communication
Error
Code Update Error Types
70
Failed to Send CUP Cmd
to Drive / No Response
From Drive
Verify the firmware images for both the autoloader and drive are
the most recent images located at
Review the firmware update readme file provided with the
firmware images.
Note: The recommended method for drive firmware update is
through the host interface using the DFU utility provided with the
firmware images. The recommended method for loader firmware
update is through the Remote Management Unit.
71
CUP Send Failed
72
Drive Update Failed,
Media Present
73
Image Size in Header Too
Big