Dell PowerVault 124T User Manual
Page 45

24
Software Error
25
Hardware Error
Message Error Types
26
Message Sender (Task )
ID Error
Verify the host backup application and device driver are at the
.
Check host adapter and SAS cables.
Power cycle the autoloader and retry the operation.
If all previous steps fail, see
Contacting Dell
.
27
Message Type Bad
28
Message Parameter Bad
Stack/Global Data Corruption Error Types
29
Invalid Element
Verify the host backup application and device driver are at the
.
Power cycle the autoloader.
Run the Random Moves test from either the Remote Management
Unit (RMU) or the Operator Control Panel (OCP).
Note: The Random Moves test requires a minimum of two
cartridges present within the autoloader.
If all previous steps fail, see
Contacting Dell
.
2A
Invalid Element Status
2B
Element Table Bad
2C
Global Data Bad
2D
Stack Data Bad
2E
Task Stack Low
2F
Task Stack Overflow
System Shutdown/Disruption Error Types
30
POST Failure
Verify that the magazines/magazine blank are fully seated.
Power cycle the autoloader.
If all previous steps fail, see
Contacting Dell
.
31
Watchdog Timer
Power cycle the autoloader.
Run the Random Moves test from either the Remote Management
Unit (RMU) or the Operator Control Panel (OCP).
Note: The Random Moves test requires a minimum of two
cartridges present within the autoloader.
see
Contacting Dell
.
32
Power Event
33
Power Down Failure
34
System Overload
35
System Performance
36
Asynchronous Stop
System Miscellaneous Error Types
37
System Cleaning Error
Cleaning slot in use.
Verify that a valid cleaning cartridge is located in the dedicated
cleaning slot indicated within the Remote Management Unit
Configuration page settings.