Dell PowerVault 124T User Manual
Page 53

CE
Motor Translation Pin
Jammed Error
CF
Motor Asynchronous Stop
Magazine Hardware Error Types
D0
Magazine Eject Failed
Ensure that the autoloader is resting on a solid flat surface, or
mounted level in a rack unit.
Remove and re-insert the magazine. Verify that the magazine
slides freely in and out of the magazine bay.
Verify that the magazine clicks and locks in place when fully
inserted.
Power cycle the autoloader and retry the operation.
If all previous steps fail, see
Contacting Dell
.
D1
Magazine Present Sensor
Bad
D2
Magazine Cam Position
Sensor Bad
Ensure that the autoloader is resting on a solid flat surface, or
mounted level in a rack unit.
Remove and re-insert the magazine. Verify that the magazine
slides freely in and out of the magazine bay.
Verify that the magazine clicks and locks in place when fully
inserted.
Power cycle the autoloader and run the Magazine Test from the
Operator Control Panel.
If all previous steps fail, see
Contacting Dell
.
D3
Magazine Sensor 1 Bad
D4
Magazine Sensor 2 Bad
D5
Magazine Flag Missing
Magazine errors may occur if the magazine sensor cannot detect
cartridge carrier flags during magazine rotation. This may be caused by
an issue with a cartridge carrier flag, a sensor problem, a physically
jammed magazine, or a sensor alignment issue caused by a mis-
inserted magazine.
Ensure that the autoloader is resting on a solid flat surface, or
mounted level in a rack unit.
Remove and inspect the magazines one at a time. Turn the white
thumbwheels on each magazine and ensure that the carriers
move freely at least one full rotation in each direction.
Verify that carrier flags are present on all slots and slot 1 has the
unique (longer) carrier flag.
Ensure that the sensors protruding from the picker into the
magazine bays are free of debris, and 'float' in and out freely
when pushed by hand.
Carefully re-insert the magazine straight into the magazine bay.
Be careful to avoid twisting or biasing the magazine up or down.
Power cycle the autoloader.
Run the Magazine Test from the operator control panel.
If all previous steps fail, see
Contacting Dell
.
D6
Magazine Flag Bad
D7
Slot Zero Not Found
D8
Multiple Slot Zero
Detected
D9
Magazine Step Tolerance
Error
DA
Magazine Calibration Lost
DB
Magazine Lost
DC
Magazine Position Error
DD
Magazine Slot Type
Invalid
DE
Magazine Slot (Gross)
Position Error
DF
Magazine Jammed Error
System Event Types
E8
Time Zone Update Event
User updated the time zone setting. No action required.
E9
Time Update Event
The system time was changed. No action required.