Dell PowerVault 124T User Manual
Page 49

74
Block Erase Failed
Verify all SAS cable connections between the host and
autoloader.
Verify no media in drive during update.
Power cycle the autoloader using the front panel power button
and retry the operation.
If all previous steps fail, see
Contacting Dell
.
75
Flash Program Failed
76
Header Corrupt
77
Checksum Error
78
Timeout During CUP
79
Reset During Drive
Update
7A
Unexpected Reset From
Drive
7B
Unexpected Message
From PSP
7C
Personality or Version
Check Failed
7D
Error During Write Buffer
Command
7E
Uncompressed EDC
Failure
7F
Image Processing Ended
Early
Server Task Error Types
80
Unexpected Response or
Data Received
Verify the host backup application and device driver are at the
.
Check host adapter and SAS cables.
Power cycle the autoloader and retry the operation.
If all previous steps fail, see
Contacting Dell
.
Servo Elevator Hardware Error Types
92
Elevator Flag Bad
Power cycle the autoloader
Run the Random Moves test from either the Remote Management
Unit (RMU) or the Operator Control Panel (OCP).
Note: The Random Moves test requires a minimum of two
cartridges present within the autoloader.
If all previous steps fail, see
Contacting Dell
.
93
Elevator Sensor Bad
97
Elevator Calibration Lost
98
Elevator Calibration
Jammed
99
Elevator Lost
9B
Elevator Position Error
Picker/Magazine Servo Error Types
A0
Servo Error
Power cycle the autoloader.
Run the Random Moves test from either the Remote Management
Unit (RMU) or the Operator Control Panel (OCP).
Also execute the Recommended Actions for "Open Front" (4B)
error type.
Note: The Random Moves test requires a minimum of two
cartridges present within the autoloader.
A1
Reserved Error Code
A2
Servo Timeout Error
A3
Position Error
A4
Servo Not Calibrated