Dell PowerVault 124T User Manual
Page 54

Front Panel Error Types
EA
LCD Busy Error
Possible LCD controller problem, software error, or communication error.
Power cycle the autoloader.
Run the Random Moves test.
If all previous steps fail, see
Contacting Dell
.
EB
LCD Goto Error
EC
Login/Password Error
Incorrect login from front panel.
Use correct login/password.
ED
Socket Error During SNTP
Barcode Error Types
F0
Bar Code Init Error
Remove magazines and inspect cartridges. Verify that valid
barcode labels are being used on all cartridges, and re-insert the
magazines.
If barcode labels are not being used, disable the barcode reader
through the Operator Control Panel or Remote Management Unit.
Run the Random Moves test from either the Remote Management
Unit (RMU) or the Operator Control Panel (OCP).
Note: The Random Moves test requires a minimum of two
cartridges present within the autoloader.
If all previous steps fail, see
Contacting Dell
.
F1
Bar Code Hardware Error
F2
Bar Code Baud Rate Error
F3
Bar Code Handshake
Error
F4
Bad/Noisy Response From
Bar Code Reader
F5
Checksum Failed
Incomplete barcode label or barcode checksum failed.
Repeat test with new cartridge or label.
If problems recur with the original cartridge or label, replace.
If all previous steps fail, see
Contacting Dell
.
F6
Barcode No Read
Barcode label not present.
Apply valid barcode label to cartridge, or disable the barcode
reader through the Operator Control Panel or Remote
Management Unit.
F7
Barcode Mismatch Error
Power cycle the autoloader.
Run the Random Moves test from either the Remote Management
Unit (RMU) or the Operator Control Panel (OCP).
Note: The Random Moves test requires a minimum of two
cartridges present within the autoloader.
If all previous steps fail, see
Contacting Dell
.
F8
Barcode Duplicate Label
Error
Duplicate barcode.
Diagnostic Error Types
F9
Diagnostic Test Failure
Power cycle the autoloader.
Re-run the failing diagnostic test.
If all previous steps fail, see
Contacting Dell
.