beautypg.com

Dell PowerVault NX300 User Manual

Page 35

background image

About Your System

35

E2113

Mem mirror OFF

on DIMM ## &

##. Power

cycle AC

The system BIOS has
disabled memory
mirroring because it has
determined one half of the
mirror has had too many
errors. "## & ##"
represents the
memory-module pair
implicated by the BIOS.

Remove AC power to the
system for 10 seconds and
restart the system.

If the problem persists,
see "Troubleshooting
System Memory" on
page 154.

I1910

Intrusion

detected.

Check chassis

cover.

System cover has been
removed.

Information only.

I1911

LCD Log Full.

Check SEL to

review all

Errors.

LCD overflow message.
A maximum of ten error
messages can display
sequentially on the LCD.
The eleventh message
instructs the user to check
the SEL for details on the
events.

Check the SEL for details
on the events.

Remove AC power to the
system for 10 seconds or
clear the SEL.

I1912

SEL full.

Review & clear

log.

The SEL is full of events
and is unable to log any
more.

Check the SEL for details
on the events, then clear
the SEL.

I1920

iDRAC6 Upgrade

Successful

optional iDRAC6 has
been upgraded
successfully.

Information only.

W1228

RAID

Controller

battery

capacity <

24hr.

Warns predictively that
the RAID battery has
less than 24 hours of
charge left.

Allow RAID battery to
charge to greater than
24 hours of
sustained charge.

If problem persists,
replace RAID battery.
See "Installing the RAID
Battery" on page 114.

Table 1-2.

LCD Status Messages (Optional) (continued)

Code

Text

Causes

Corrective Actions

book.book Page 35 Thursday, August 13, 2009 7:27 AM