Installing the System Board Shroud
1 Align the shroud using center of the numbered fan bays as a guide and
locate the tab projection on the left side of the fan module numbered 3.
See Figure 3-13.
2 Push the system board shroud down until all edges are seated in the slots,
securing the shroud to the system board.
3 Close the system. See "Opening and Closing the System" on page 82.
iDRAC6 Express Card (Optional)
Installing an iDRAC6 Express Card
CAUTION:
Many repairs may only be done by a certified service technician. You
should only perform troubleshooting and simple repairs as authorized in your
product documentation, or as directed by the online or telephone service and
support team. Damage due to servicing that is not authorized by Dell is not covered
by your warranty. Read and follow the safety instructions that came with the
product.
1 Turn off the system, including any attached peripherals, and disconnect
the system from the electrical outlet.
2 Open the system. See "Opening the System" on page 82.
3 To install the iDRAC6 Express card:
4 Insert the notch on the Integrated Dell Remote Access Controller 6
(iDRAC6) Express card into the clip on the system board.
a
Align the front edge of the card with the connector on the system
board. See Figure 6-1 for the location of the connector.
b
Press the card down until it is fully seated. See Figure 3-14.
When the front of the card is fully seated, the plastic standoff tab
snaps over the edge of the holder.