Troubleshooting a wet system – Dell PowerVault NX300 User Manual

Page 150

background image

150

Troubleshooting Your System

Change the autonegotiation setting, if possible.

Use another connector on the switch or hub.

If you are using a NIC card instead of an integrated NIC, see the
documentation for the NIC card.

4 Ensure that the appropriate drivers are installed and the protocols are

bound. See the NIC's documentation.

5 Enter the System Setup program and confirm that the NIC ports are

enabled. See "Integrated Devices Screen" on page 64.

6 Ensure that the NICs, hubs, and switches on the network are all set to the

same data transmission speed. See the documentation for each network
device.

7 Ensure that all network cables are of the proper type and do not exceed the

maximum length.
If all troubleshooting fails, see "Getting Help" on page 177.

Troubleshooting a Wet System

CAUTION:

Many repairs may only be done by a certified service technician. You

should only perform troubleshooting and simple repairs as authorized in your
product documentation, or as directed by the online or telephone service and
support team. Damage due to servicing that is not authorized by Dell is not covered
by your warranty. Read and follow the safety instructions that came with the
product.

1 Turn off the system and attached peripherals, and disconnect the system

from the electrical outlet.

2 Open the system. See "Opening the System" on page 82.
3 Remove the following components from the system. See "Installing

System Components" on page 79.

Cooling shroud

Hard drives

Vflash SD cards

USB memory keys

NIC hardware key

book.book Page 150 Thursday, August 13, 2009 7:27 AM