beautypg.com

Dell PowerVault NX300 User Manual

Page 34

background image

34

About Your System

E2021

Incorrect

memory

configuration.

Review User

Guide.

Incorrect memory
configuration.

Check screen for specific
error messages. See
"Troubleshooting System
Memory" on page 154.

E2022

General

failure

during POST.

Check screen

message.

General failure after video. Check screen for specific

error messages.

E2023

BIOS Unable to

mirror memory.

Check DIMMs.

The system BIOS could
not enable memory
mirroring because of a
faulty memory module or
an invalid memory
configuration.

See "Troubleshooting
System Memory" on
page 154.

E2110

Multibit Error

on DIMM ##.

Reseat DIMM.

The memory module in
slot “##” has had a
multi-bit error (MBE).

See "Troubleshooting
System Memory" on
page 154.

E2111

SBE log

disabled on

DIMM ##.

Reseat DIMM.

The system BIOS has
disabled memory
single-bit error (SBE)
logging and will not log
anymore SBEs until the
system is rebooted. "##"
represents the memory
module implicated by
the BIOS.

Remove AC power to the
system for 10 seconds and
restart the system.

If the problem persists,
see "Troubleshooting
System Memory" on
page 154.

E2112

Memory spared

on DIMM ##.

Power cycle

AC.

The system BIOS has
spared the memory
because it has determined
the memory had too many
errors. "##" represents the
memory module
implicated by the BIOS.

Remove AC power to the
system for 10 seconds and
restart the system.

If the problem persists,
see "Troubleshooting
System Memory" on
page 154.

Table 1-2.

LCD Status Messages (Optional) (continued)

Code

Text

Causes

Corrective Actions

book.book Page 34 Thursday, August 13, 2009 7:27 AM