Controls and indicators, Power, Physical – Dell OptiPlex GX1p User Manual
Page 57: Environmental
Controls and Indicators
Reset control
push button
Power control
push button
Power indicators
green LEDs (one on front panel, one on riser board); blinking green in sleep state
Hard-disk drive access indicator
green LED
Link integrity indicator
(on optional integrated NIC connector)
green LED
Activity indicator (on optional integrated NIC
connector)
yellow LED
Power
DC power supply:
Wattage
200 W
Heat dissipation
913 BTUs (fully loaded system without monitor)
Voltage
90 to 135 V at 60 Hz; 180 to 265 V at 50 Hz
Backup battery
3-V CR2032 coin cell
Physical
Height
16.5 cm (6.5 inches)
Width
41.9 cm (16.5 inches)
Depth
44.5 cm (17.5 inches)
Weight
12.7 kg (28.0 lb) or more, depending on options installed
Environmental
Temperature:
Operating
10 to 35C (50 to 95F)
Storage
-40 to 65C (-40 to 149F)
Relative humidity
8% to 80% (noncondensing)
Maximum vibration:
Operating
0.25 G at 3 to 200 Hz at 1 octave/min
Storage
0.5 G at 3 to 200 Hz at 1 octave/min
Maximum shock:
Operating
left side (vertical orientation) and bottom half-sine pulse with a change in velocity of 20
inches/sec (50.8 cm/sec)
Storage
27-G faired square wave with a velocity change of 200 inches/sec (508 cm/sec)
Altitude:
Operating
-16 to 3048 m (-50 to 10,000 ft)
Storage
-16 to 10,600 m (-50 to 35,000 ft)
NOTE: For the full name of an abbreviation or acronym used in this table, see the Glossary in the online System User's Guide.