Aux2 – Carrier AQUASNAP MPW015-045 User Manual

Page 17

background image

17

COMP A2

TRAN1

H2

H3

H4

SECONDARY 24V

RED

3

3

2

2

1

1

J2

BRN

VIO

2

2

1

J1

1

3

3

FU3

SW2

C1

A1

B1

H1

X3

CONNECT FOR APPROPRIATE PRIMARY VOLTAGE SEE TABLE 1

2

4

6

CB1A

11

12

13

TO FUSED

DISCONNECT

PER NEC

OPTIONAL

DISCONNECT

3.2 AMPS

CB3

1

2

3

T3

T1

T2

T3

T1

T2

3

2

1

GRN/YEL

GRN/YEL

XF

RED

11

21

12

22

13

23

CA1

BLK

YEL

BLU

11

21

12

22

13

23

CA2

11

12

13

21

22

23

CCB-1

BLK

YEL

BLU

BLK

YEL

BLU

YEL

BLU

BLK

YEL

BLU

BLK

11

12

13

21

22

23

CCB-2

BLK

YEL

BLK

015,020,040: 380V,460V,575V ONLY

030,045: 460V,575V ONLY

BLU

YEL

BLU

T3

T1

T2

3

2

1

GRN/YEL

11

21

12

22

13

23

CA3

BLK

YEL

BLU

11

12

13

21

22

23

CCB-3

BLK

YEL

BLU

YEL

BLU

BLK

BLU

BLU

BLU

YEL

YEL

YEL

BLK

BLK

BLK

BLK

YEL

CH-A1

BLK

BLK

BLK

YEL

L1

T1

L2

T2

BLK

YEL

CH-A2

BLK

BLK

BLK

YEL

CH-A3

BLK

BLK

YEL

BLK

015,020,040: 208/230V ONLY 030,045: 202/230V,380V ONLY

MBB

BRN

VIO

2

1

UPC FIOP

UPC

GND

HOT

24VAC

BRN

VIO

12

2

11

1

J1

DGS FIOP

AUX2

BRN

RED

3

3

2

2

1

1

J2

2

J1

1

3

FIOP/ACCESSORY

EMM

FU1

BLK

FU2

YEL

GRN/YEL

RED

VIO

VIO

BRN

BRN

PRIMARY

WHT

11

X2

380V UNITS ONLY

NOT USED ON 380V UNITS

FB1

BLK

YEL

NOTES:

1. FACTORY WIRING IS IN ACCORDANCE WITH UL 1995 STANDARDS. ANY FIELD MODIFICATIONS OR ADDITIONS MUST BE IN COMPLIANCE WITH ALL APPLICABLE CODES.

C MIN WIRE FOR FIELD POWER SUPPLY.

3. ALL FIELD INTERLOCK CONTACTS MUST HAVE A MIN RATING OF 2 AMPS

@ 24VAC SEALED. SEE FIELD INTERLOCK WIRING.

4. COMPRESSOR AND FAN MOTORS ARE THERMALLY PROTECTED-- THREE PHASE MOTORS PROTECTED AGAINST PRIMARY SINGLE PHASE CONDITIONS.

5. TERMINALS 14

& 15 OF LVT ARE FOR FIELD CONNECTION

OF REMOTE ON-OFF. THE CONTACT MUST BE RATED FOR DRY CIRCUIT APPLICATION CAPABLE OF HANDLING A 5VDC 1 MA TO 20 MA LOAD.

6. FOR 500 SERIES UNIT OPERATION AT 208-3-60V LINE VOLTAGE, TRAN1 PRIMARY CONNECTIONS MUST BE MOVED TO TERMINALS H3

& H4.

8. MP-A1 NOT USED IN THE FOLLOWING UNITS: 015,020: ALL UNITS

9. MP-A2 NOT USED IN THE FOLLOWING UNITS: 015,020: ALL UNITS

10. MP-A3 NOT USED IN THE FOLLOWING UNITS:

11. JUMPER PLUG REQUIRED WHEN MP NOT USED

WHT

(040,045 ONLY)

VOLTAGE

SERIES

TERMINAL

CONNECTIONS

FOR PRIMARY SIDE

575-3-60

100

H1 & H5

380-3-60

200

H1 & H2

230-3-60

500

H2 & H4

208-3-60

500

H3 & H4

460-3-60

600

H1 & H4

TABLE 1

7. MAX LOAD: 5VA SEALED, 10VA INRUSH

(040,045 ONLY)

BLK

YEL

(MPA ONLY)

(MPA ONLY)

WHT

BLK

YEL

FU4

FU5

UNIT VOLTAGE

REPLACE

WITH

FNQ-R-3

FU1 & FU2

FUSE NUMBER

380-3-60

TRAN SIZE

200VA

FNQ-R-2

208/230-3-60

FNQ-R-10

FU3 (24V)

380-3-60,460-3-60,575-3-60

250VA

208/230-3-60

460-3-60

575-3-60

FNQ-R-1.5

FNQ-R-1.5

FU4 & FU5

380-3-60,460-3-60,575-3-60

NONE

208/230-3-60

(040,045 ONLY)

(040,045 ONLY)

12. IF CHILLED WATER PUMP INTERLOCK IS USED,

REMOVE JUMPER FROM TERMINAL 16 TO 17 AND

WIRE INTERLOCK CONTACT ACROSS TERMINALS 16 & 17.

030-045: 460V UNITS WITHOUT DIGITAL SCROLL

030-045: 460V UNITS

040,045: 460V UNITS

FNQ-R-3

1

2

3

TB3

X1

380V ONLY

PL11-2

PL11-1

PL12-2

PL12-1

CCH

PL13-2

PL13-1

STANDARD TERMINAL

BLOCK

PER NEC

TO FUSED DISCONNECT

21

22

23

TB1A

EQUIP GND

COMP A1

COMP A3

21

380V UNITS ONLY

NEUTRAL

CSB-A1

CSB-A2

CSB-A3

L1

L2

L3

L1

L2

L3

Fi

g.

4 — Typ

ic

a

l

Po

wer

Wi

ri

ng Sche

ma

ti

c —

3

0

MP01

5-

04

5 Un

it

s

a30-4965