Installation Instructions

CONTENTS

Page

GENERAL

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1

SAFETY CONSIDERATIONS

. . . . . . . . . . . . . . . . . . . 1,2

INSTALLATION

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-16

Location

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

Step 1

— Inspect Shipment

. . . . . . . . . . . . . . . . . . . . 2

Step 2

— Position the Unit

. . . . . . . . . . . . . . . . . . . . . 2

Step 3

— Place the Unit

. . . . . . . . . . . . . . . . . . . . . . . . 7

Step 4

— Check Compressor Mounting

. . . . . . . . 7

Step 5

— Make Piping Connections

. . . . . . . . . . . . 7

• 30MPA SYSTEM CONDENSER

• 30MPW CONDENSER DESCRIPTION

• 30MPW CONDENSER

• EVAPORATOR DESCRIPTION

• EVAPORATOR PIPING

• AIR SEPARATION

Step 6

— Fill the Chilled Water Loop

. . . . . . . . . . .13

• WATER SYSTEM CLEANING

• FILLING THE SYSTEM

Step 7

— Make Electrical Connections

. . . . . . . . .14

• FLOW SWITCH

• CONTROL BOX, POWER SECTION

• CONTROL BOX, CONTROLS SECTION

• CONTROL BOX, FIELD CONTROL WIRING

SECTION

• UNBALANCED 3-PHASE SUPPLY VOLTAGE

GENERAL

These installation instructions cover the 30MPA, MPW units

with ComfortLink controls. The 30MPA units are condenserless

units and the 30MPW units are all fluid cooled.

SAFETY CONSIDERATIONS

Installing, starting up, and servicing this equipment (Fig. 1

and 2) can be hazardous due to system pressures, electrical

components, and equipment location (roofs, elevated struc-

tures, etc.). Model number structure is shown in Fig. 3.

Only trained, qualified installers and service technicians

should install, start up, and service this equipment.

When working on the equipment, observe precautions in the

literature and on tags, stickers, and labels attached to the

equipment.
• Follow all safety codes.

• Wear safety glasses and work gloves.

• Use care in handling, rigging, and setting bulky

equipment.

.

WARNING

Electrical shock can cause personal injury and death. Shut

off all power to this equipment during installation. There

may be more than one disconnect switch. Tag all discon-

nect locations to alert others not to restore power until work

is completed.

Fig. 1 — 30MPA Unit

a30-5029

Fig. 2 — 30MPW Unit

a30-5030

AQUASNAP

®

30MPA,MPW015-045

Liquid Chillers

with Scroll Compressors

and COMFORTLINK™ Controls