Configuration and Activation 5-15
notification for the wireless communication unit, when
applicable. ADS recommends using -95 dBm for the low
signal strength.
Low Battery FlowShark, FlowShark IS, and IS
External (These parameters do not apply to the
RainAlert II monitor)
Low Battery FlowAlert/RainAlert II Enter the voltage
below which you want Profile to provide notification for
FlowAlert and RainAlert II monitors. ADS recommends
leaving the default battery voltage unchanged.
Note: Notification of low battery voltage or signal
strength occurs during the data collection process, during
monitor activation, and when receiving TCP/IP
communication status. View the associated logs through
the Diagnostics tool and Log Viewer in the Profile
software.
4. Select the OK button.