4-20
ADS RainAlert II Manual
them, just be sure they are securely connected together when
the phone wire is spliced to the green/white and red/black pairs.
2. Connect the green/white and red/black pairs to the phone wires.
Use crimp type or other outdoor rated connection methods to
splice the monitor cable to the phone cable.
3. Thoroughly wrap the completed junction with rubber tape. Be
sure to extend the tape up the cables beyond the junction to
ensure a good moisture seal and to reinforce the connection.
4. Identify the TELCO/EXT ANTENNA port on the bottom of
the monitor.
Product Complies With:
FCC Part 15, Part 68
US: 6KDMD06AHS1
Contains GSM/GPRS Transceiver
FCC ID: MIVGSM0108
TIPPING
BUCKET
SERIAL
COMM.
EXTERNAL
AC/DC PWR.
TELCO/EXT
ANTENNA
TELCO/EXT ANTENNA (communications) port on the bottom of the monitor
5. Seat, fasten, and secure the completed telephone cable onto the
TELCO/EXT ANTENNA port on the monitor. Tighten the
connector in a clockwise direction until it clicks. Verify that it
is seated correctly.