Providing Telephone Service
Providing telephone service to the RainAlert II monitor equipped
for landline communication (ADS p/n 6000-RAL) involves the
following steps:
Running the telephone cable between the monitor and service
locations
Mounting the lightning protection module
Preparing the telephone cable
Wiring the telephone cable to the monitor
Wiring the telephone cable to the lightning protection module
Wiring the lightning protection module to the network interface
box
Warning: To avoid possible shock, make all connections
to the monitor before wiring to the lightning protection
module and the telephone company’s network interface
box.
Running the Telephone Cable Between the
Monitor and Service Locations
Safety Note: Always disconnect the telephone line at the
ONI/Network Interface while performing field wiring.
Dangerous voltages (100 VAC) are present when the line
is ringing. Connect to the telephone company line only
after all other wiring is complete.