Specifications A-3
Printed Circuit Board (ADS p/n 6000-0001)
The following table contains the specifications for the printed
circuit board.
Processor
Texas Instruments VC33 DSP (Digital Signal
Processor)
Functions
Performs and processes all requests for rain
data, executes all math calculations, performs
MLI-related functions based on user
configuration, performs alarm handling, and
performs multi-tasking monitor operations
Memory
1 megabyte non-volatile (program, configuration,
and data storage) and 512 kilobytes static RAM
Data Storage
365 days at a 15-minute sample rate
Sample Rates
Minutes: 1, 2, 5, 15, 30
Hours: 1, 2, 12, 24
Clock
Battery-backed real-time clock (RTC) module
Communications
Wireless modem: Enfora
™
Dual band 850/1900
MHZ GSM/GPRS; FCC ID MIVGSM0108; fixed
address via AT&T custom APN; refreshed every
4 hours via hard-attach
Landline modem: Multitech Model MT5600SMI;
FCC ID 6KDMD06AHS1; 19.2K baud with
fallback to 9600 and 1200 as required for
reliable communication; regular 2-wire voice
grade POTS service line
Serial/Direct Connect: RS-232
Comm Protocol
AccuYapp for configuration and diagnostics
Yapp for data collects and cryouts
LED Diagnostic
Readings
Wireless signal strength
Battery voltage
Monitor IP address