Pak 200i – Tweco PAK 200i User Manual
Page 35
PAK 200i
Manual 0-5335
INSTALLATION
3-11
1. Unscrew and remove the shield cup from the Torch Head.
�. Using the multi-purpose wrench (5/� inch slot) remove the tip.
3. Tilt the Torch Head to remove the gas distributor. The end of the multi�purpose wrench can be used to help
remove the gas distributor.
Multi-Purpose Wrench
(Catalog Number 20-0001)
Used for Electrodes
Used for 11/16" ( 17.5 mm)
Across Tip Flats
Gas Distributor Notch
Used with 11/16" (17.5 mm)Tip
Used for 5/8" (15.9 mm)
Across Tip Flats
Gas Distributor Notch
Used with 5/8" (15.9 mm)Tip
This Side
Towards Torch
A-01639
Electrode
Shield Cup
Tip
Gas
Distributor
Torch Head
Water Tube Extension
(Gouging Only)
A-02188
Figure 3�16: Multi�Purpose Wrench and Gas Distributor Disassembly
�. Using the multi-purpose wrench (electrode area) remove the electrode.
5. Remove gouging water extension tube, if used.
6
. Install the desired electrode for the operation into the Torch Head. The circular area around the wrench used for
electrodes will also align the electrode in the Torch Head. This will prevent installing the electrode on an angle
and cross threading the electrode in the Torch Head.
7. Install gouging water extension tube if required.
8. Install the desired gas distributor and tip for the operation into the Torch Head.
NOTE
Be careful not to overtighten the electrode and tip when reinstalling.
9. Hand tighten the shield cup until it is seated on the Torch Head. If resistance is felt when installing the cup,
check the threads before proceeding.