beautypg.com

Pak 200i – Tweco PAK 200i User Manual

Page 35

background image

PAK 200i

Manual 0-5335

INSTALLATION

3-11

1. Unscrew and remove the shield cup from the Torch Head.

�. Using the multi-purpose wrench (5/� inch slot) remove the tip.

3. Tilt the Torch Head to remove the gas distributor. The end of the multi�purpose wrench can be used to help

remove the gas distributor.

Multi-Purpose Wrench

(Catalog Number 20-0001)

Used for Electrodes

Used for 11/16" ( 17.5 mm)

Across Tip Flats

Gas Distributor Notch

Used with 11/16" (17.5 mm)Tip

Used for 5/8" (15.9 mm)

Across Tip Flats

Gas Distributor Notch

Used with 5/8" (15.9 mm)Tip

This Side

Towards Torch

A-01639

Electrode

Shield Cup

Tip

Gas

Distributor

Torch Head

Water Tube Extension

(Gouging Only)

A-02188

Figure 3�16: Multi�Purpose Wrench and Gas Distributor Disassembly

�. Using the multi-purpose wrench (electrode area) remove the electrode.

5. Remove gouging water extension tube, if used.

6

. Install the desired electrode for the operation into the Torch Head. The circular area around the wrench used for

electrodes will also align the electrode in the Torch Head. This will prevent installing the electrode on an angle

and cross threading the electrode in the Torch Head.

7. Install gouging water extension tube if required.

8. Install the desired gas distributor and tip for the operation into the Torch Head.

NOTE

Be careful not to overtighten the electrode and tip when reinstalling.

9. Hand tighten the shield cup until it is seated on the Torch Head. If resistance is felt when installing the cup,

check the threads before proceeding.