Gas Control communications reply fault

Communication has been established but Gas Control did not reply to a request from the CCM in the time al-

lowed. Likely cause is Fiber-optic problems (see code 501) or if problem persists defective Gas Control main PCB.

303

Gas Pressure fault

Gas pressure faults only show up when you try to start the torch, not during purging or setting flows .

With the Auto-Cut 200 XT, PAK 200i and the Auto-Cut 300 XT (GCM 1000 XT), the gas pressure sensor is only

on the plasma gas and is in series with Run/Set switch. A 303 code here indicates either plasma gas missing or

very low pressure, less than 50 PSI, or RUN/SET switch is in SET position.

Starting with GCM2010 revision AG we measure inlet pressure of both plasma and shield gas at the inlet of

the gas selection manifold. If pressure is either too low or too high it sets 303 code. Earlier revision should not

display 303 code. GCM�010 will display which gas is the problem and its actual pressure. The pressure at the

point where it is measured should be in the range of 100-135 PSI. Exception is for shield gas if the Gas switch

is set to Pressure then the min pressure can be 85 PSI.

In the GCM �010 Gas Control, on the main PCB, measure between test points TP1 (ground) and TP18 (shield)

and TP19 (plasma) to measure the output of the pressure sensors. Voltage should be between 2.6V to 3.5V for

100-135 PSI. With shield switch set to pressure low limit is 2.1V. Whichever gas is outside those limits will

be the one causing the fault. Remember the pressure may drop during operation, set the code, then recover

displaying L303 when you are measuring it.

• To test for faulty pressure sensor or inadequate gas supply with too much restriction. On the GCM 2010

place the Mode switch to SET Plasma & Shield, turn the mechanical pressure regulators to max pressure

and compare mechanical gauges with the pressure display. If the pressure display doesn’t approximately

match the gauge the sensor is likely defective. If the gauge and the pressure display both show low pres-

sure the supply to the gas control has too much restriction. Perhaps the hose is too long or too small.

304

Gas Control not ready

This is the normal code when the gas control is conducting a purge at start up or when the process is loaded

or changed or when the plasma system has been disabled and is returned to “Enable”. If it is a GCM 2010 the

Mode switch may not be set to the RUN mode.

Code 304 combined with 204 & 402 when the Plasma Enable on the GCM 2010 gas control is set to disable can

indicate a fault in the CCM I/O PCB. When switching back to Enabled the pump will not restart so continues

to display 4-2 indicating no coolant flowing.

Normally the code during a disable should be 101. Circuits on the I/O PCB detect the Plasma Enable is disabled

and send signal to the microcontroller in the CCM. If a fault in the CCM prevents that signal from getting sent

to the microcontroller it doesn’t know the system is disabled so it sets these other 3 codes.

305

Gas Control Protocol Error

Application error or firmware incompatibility fault. Consult factory for latest firmware update. Possible elec-

tromagnetic interference from the Arc Starter; inspect grounding, bonding, and isolation.

306

Not Used. This is one of the reserved codes from the earlier product.

307

Gas Control returns wrong command sequence.

Firmware incompatibility. Consult factory for latest firmware update. Possible electromagnetic interference

from the Arc Starter; inspect grounding; bonding; and isolation.

308

Mismatch between the CCM and gas control type.

The Auto-Cut XT CCM is designed to work with the GCM 1000 (AC 300 XT) or the built in gas control of the AC

�00 XT. Attempting to use a GCM �010 or DFC 3000 Auto Gas Control on an Auto-Cut will result in a 308 code.

Similarly attempting to use a CCM from an Auto-Cut XT in an Ultra-Cut XT supply will also result in a 308 code.