Pak 200i – Tweco PAK 200i User Manual

Page 125

background image

PAK 200i

Manual 0-5335

APPENDIX

A-45

External or CNC Plasma Enable D2, CNC PLASMA ENABLE LED, is not on.

• LED D2 on the CCM will be on if this input is satisfied either with the jumper on TB1- 1 & 2 or an external

or CNC switch. If the jumper is in place and the LED is not on, the CCM is most likely defective.

• If the jumper at CCM TB1-1 & 2 has been removed to use an external switch, install a jumper as a test. If

D2 illuminates the problem is with the switch or it’s wiring.

• If Plasma Enable is wired through the CNC cable remove the cable and jumper J15 pins 25 & 26. If D2

still not on there may be a problem in the wiring inside the power supply.

Plasma Enable from Gas Control or TSC 3000

If the External or CNC Plasma Enable is satisfied, D2 is on, a relay K7 on the CCM I/O PCB energizes supply-

ing +15V to another relay K1 on the I/O board. An active low signal, /Plasma Enable-HMI, comes from TSC

3000 Plasma Enable switch via the Relay PCB or if TSC 3000 is not installed the signal originates on the Relay

PCB. This signal applies ground to the K1 relay energizing it and lighting the LED, D3 on the I/O board. K1’s

contacts go back to the Relay board and the Gas control connector J55 to allow turning on relays and solenoids

on those devices. The AC 200 XT and PAK 200i do not use the separate Gas Control or the TSC 3000.

Art # 12304

1

5

3

2

4

K7

1

8

4

2

6

7

3

5

PLASMA ENABLE

K1

/PLASMA ENABLE - HMI

GND

24 VAC

24 VAC

TSC 3000

RELAY PCB

1

5

3

2

4

PLASMA ENABLE - CNC

K6

+15VDC

GREEN

D3

PS_ENABLE

To

Relay

PCB

To Gas

Control

CCM I/O PCB

GREEN

D2

Plasma Enable SW

GCM 2010

(or jumper in

other gas controls)

-1
-3

-5

-6

J54

J55

XT Power Supply

Simplified schematic, all connectors are not shown.

Refer to unit schematics for details.

J61

J56

-1
-2

Jumper in

AC 200 XT

J26-6
J26-7

GCM 1000 XT

J56

J54

When the circuit between J54-1 & 3 is closed (jumper,

etc.) K7 is energized and requires a Plasma Enable SW

or equivlant to enable the plasma.

With J54-1 & 3 open K7 is denergized and it's NC

contacts complete the Plasma Enable-HMI circuit.

-1
-2

-2

-1

-5

-6

-3

-1

-5

-6

-3

-1

(AC 300 XT

DMC 3000)

J25

-15

-22

J30

-20

-25

Plasma

Enable

SW

iCNC

XT 2 &

XT 242

J54

-5

-6

-3

-1

iCNC

XT 211

HMI PLASMA

ENABLE BYPASS

If a TSC 3000 is not connected or unit is an Auto-Cut, K7 on the Relay PCB is de-energized and GND is con-

nected through its normally closed contacts. If the TSC is connected, 24 VAC through a jumper in the TSC 3000

energizes K7, opening its NC contacts and now GND connects through the TDC 3000 Plasma Enable switch.

The GND obtained by either path passes through the GCM �010 Plasma Enable switch or through a jumper

(J56-1 to J56-2) present in the other gas controls (GCM 1000 XT or DMC 3000) and is connected to the coil of K1

on the I/O PCB. If the CNC Plasma Enable is also active (D2 is on) +15V will be connected to K1’s coil through

the relay K7 on the I/O PCB. This energizes K1 and turns on D3, Plasma Enable LED. The contacts of K1 go

back to the Relay board and to the Gas control to enable power to connect to relays and solenoids in those items.

Troubleshooting:

1. If both D2 and D3 are on and you still have 101 fault replace the CCM. Otherwise go to step 2 except if

it’s an AC 200 XT skip to step 4.

2. If D3 is not on and there is a TSC 3000 in use remove its cable from J54. K7 on the Relay board will de-

energize and satisfy the Plasma Enable to K1. If D3 is now on problem was in the TSC 3000 or its cable.

Otherwise reconnect the cable.

3. For an Ultra-Cut with DFC 3000 or GCM 2010 or an Auto-Cut 300 with a GCM 1000 XT remove the cable

from J55 the gas control connector and jumper pins 1 & 2. If D3 is on now problem is in the Gas Control

or its cable. If D3 still not on replace the Gas Control cable.

4. If neither of the above steps works, on the CCM I/O board, jumper J26-7 to GND (TP1 on I/O). If D2 is

on and D3 still does not light then replace the CCM.