Rockwell Automation 2198-Hxxx Kinetix 5500 Drive Systems Design Guide User Manual
Page 92

92
Rockwell Automation Publication GMC-RM009D-EN-P - June 2014
Kinetix 5500 Drive Systems
Kinetix 5500 (400V-class operation) Drives/MP-Series Linear Stage Curves
45.0
89.9
134.9
179.8
224.8
269.8
0
200
400
600
800
1000
1200
1400
314.7
0
Velocity (mm/s)
50
200
150
0
300
250
100
2198-H008-ERSx and MPAS-B6xxx1-V05SxA
Force
(N)
Force
(lb)
Intermittent curve represents
460V and 400V inputs
1000
800
600
400
200
0
224.8
179.8
134.9
89.9
45.0
0
Velocity (mm/s)
200
800
600
0
1200
1000
400
2198-H008-ERSx and MPAS-B6xxx2-V20SxA
Force
(N)
Force
(lb)
Intermittent curve represents
460V and 400V inputs
Force
(N)
Force
(lb)
45.0
89.9
134.9
179.8
224.8
269.8
0
200
400
600
800
1000
1200
1400
314.7
0
Velocity (mm/s)
50
200
150
0
300
250
100
2198-H008-ERSx and MPAS-B8xxx1-V05SxA
1020 mm
900 mm
< 780 mm
Intermittent curve
represents 460V and
400V inputs
Force
(N)
Force
(lb)
1000
800
600
400
200
0
224.8
179.8
134.9
89.9
45.0
0
Velocity (mm/s)
200
800
600
0
1200
1000
400
2198-H008-ERSx and MPAS-B8xxx2-V20SxA
< 660 mm
1020 mm
900 mm
780 mm
Intermittent curve
represents 460V and
400V inputs
Force
(N)
Force
(lb)
45.0
89.9
134.9
179.8
224.8
269.8
0
200
400
600
800
1000
1200
1400
314.7
0
Velocity (mm/s)
50
200
150
0
300
250
100
2198-H008-ERSx and MPAS-B9xxx1-V05SxA
1020 mm
900 mm
< 780 mm
Intermittent curve
represents 460V and
400V inputs
Force
(N)
Force
(lb)
1000
800
600
400
200
0
224.8
179.8
134.9
89.9
45.0
0
Velocity (mm/s)
200
800
600
0
1200
1000
400
< 660 mm
1020 mm
900 mm
780 mm
2198-H008-ERSx and MPAS-B9xxx2-V20SxA
Intermittent curve
represents 460V and
400V inputs
= Intermittent operating region
= Continuous operating region
= System operation with 400V AC rms input voltage
= System operation for specified stroke length