79
Kinetix 5500 Drive Systems
Performance Specifications with Frame 50 Linear Thrusters
Linear Thruster
Cat. No.
Velocity, max
460V AC
m/s
System Continuous
Stall Current
Amps 0-pk
System Continuous
Stall Force
N (lb)
System Peak
Stall Current
Amps 0-pk
System Peak
Stall Force
N (lb)
Rated Output
460V AC
kW
Kinetix 5500 Drives
(480V AC input)
LDAT-S051010-DD
x
2.8
3.1
119 (27)
11.4
363 (82)
0.34
2198-H015-ERS
x
LDAT-S051020-DD
x
3.7
0.43
LDAT-S051030-DD
x
4.1
0.49
LDAT-S051040-DD
x
4.4
0.53
LDAT-S051050-DD
x
4.7
0.55
LDAT-S052010-DD
x
3.7
6.2
251 (56)
22.7
727 (163)
0.92
2198-H025-ERS
x
LDAT-S052020-DD
x
4.8
1.20
LDAT-S052030-DD
x
5.0
1.24
LDAT-S052040-DD
x
LDAT-S052050-DD
x
LDAT-S052010-ED
x
3.7
3.1
11.4
0.80
2198-H015-ERS
x
LDAT-S052020-ED
x
4.6
0.98
LDAT-S052030-ED
x
4.6
1.02
LDAT-S052040-ED
x
LDAT-S052050-ED
x
LDAT-S053010-DD
x
4.1
9.4
378 (85)
34.2
1093 (246)
1.56
2198-H040-ERS
x
LDAT-S053020-DD
x
5.0
1.87
LDAT-S053030-DD
x
…
LDAT-S053050-DD
x
LDAT-S053010-ED
x
…
LDAT-S053050-ED
x
3.5
3.1
11.4
1.04
2198-H015-ERS
x
LDAT-S054010-DD
x
4.4
12.4
509 (114)
45.5
1453 (327)
2.26
2198-H040-ERS
x
LDAT-S054020-DD
x
…
LDAT-S054050-DD
x
5.00
2.53
LDAT-S054010-ED
x
4.4
6.2
22.7
1.87
2198-H025-ERS
x
LDAT-S054020-ED
x
…
LDAT-S054050-ED
x
5.0
2.05