VPL-B0753F
6600
4.09
2.16 (19.0)
17.70
6.55 (58.0)
0.65 (0.87)
6600
2198-H015-ERS
x
18.90
7.02 (62.0)
2198-H025-ERS
x
VPL-B0753M
8000
6.12
2.28 (20.0)
17.70
5.13 (45.0)
0.82 (1.10)
8000
2198-H015-ERS
x
25.34
7.35 (65.0)
2198-H025-ERS
x
VPL-B1001M
6000
3.61
1.93 (17.0)
8.80
3.22 (28.0)
1.14 (1.53)
6000
2198-H008-ERS
x
10.38
3.78 (33.0)
2198-H015-ERS
x
VPL-B1002E
3300
3.44
3.39 (30.0)
8.80
6.47 (57.0)
1.12 (1.50)
3300
2198-H008-ERS
x
10.69
7.82 (69.0)
2198-H015-ERS
x
VPL-B1002M
6000
6.24
3.39 (30.0)
17.70
6.80 (60.0)
1.86 (2.49)
6000
2198-H015-ERS
x
20.33
7.82 (69.0)
2198-H025-ERS
x
VPL-B1003C
2500
3.41
4.18 (37.0)
8.80
9.29 (82.0)
0.96 (1.29)
2500
2198-H008-ERS
x
10.61
11.15 (99.0)
2198-H015-ERS
x
VPL-B1003F
4750
6.14
4.18 (37.0)
17.70
9.76 (86.0)
1.65 (2.21)
4750
2198-H015-ERS
x
20.20
11.15 (99.0)
2198-H025-ERS
x
VPL-B1003T
7000
9.58
4.18 (37.0)
28.30
9.76 (86.0)
1.77 (2.37)
7000
2198-H025-ERS
x
28.80
11.15 (99.0)
2198-H040-ERS
x
VPL-B1152C
2250
3.13
5.10 (45.0)
8.80
10.80 (95.0)
1.06 (1.42)
2250
2198-H008-ERS
x
10.74
13.12 (116)
2198-H015-ERS
x
VPL-B1152F
4500
6.17
5.10 (45.0)
17.70
10.95 (97.0)
1.40 (1.88)
4000
2198-H015-ERS
x
21.19
13.12 (116)
2198-H025-ERS
x
VPL-B1152T
6500
10.81
5.08 (45.0)
28.30
12.14 (107)
2.29 (3.07)
6500
2198-H025-ERS
x
32.10
13.12 (116)
2198-H040-ERS
x
VPL-B1153E
3200
6.13
6.55 (58.0)
17.70
16.85 (149)
1.75 (2.35)
3200
2198-H015-ERS
x
21.33
20.33 (180)
2198-H025-ERS
x
VPL-B1153F
5000
8.88
6.55 (58.0)
28.30
18.30 (162)
2.30 (3.08)
5000
2198-H025-ERS
x
33.0
20.33 (180)
2198-H040-ERS
x
VPL-B1303C
2250
6.30
8.80 (78.0)
17.70
19.83 (175)
1.83 (2.45)
2250
2198-H015-ERS
x
18.47
20.72 (183)
2198-H025-ERS
x
VPL-B1303F
4000
10.10
8.80 (78.0)
28.30
19.85 (175)
2.82 (3.78)
4000
2198-H025-ERS
x
31.0
20.72 (183)
2198-H040-ERS
x
VPL-B1304C
2150
7.0
10.29 (91.0)
17.70
22.55 (199)
1.75 (2.35)
2150
2198-H015-ERS
x
22.3
28.45 (252)
2198-H025-ERS
x
VPL-B1304E
3500
9.44
10.29 (91.0)
28.30
25.03 (221)
2.82 (3.78)
3500
2198-H025-ERS
x
33.76
28.45 (252)
2198-H040-ERS
x
VPL-B1306C
2500
10.80
13.38 (118)
28.30
31.21 (276)
2.46 (3.30)
2500
2198-H025-ERS
x
32.94
34.62 (306)
2198-H040-ERS
x
VPL-B1306F
4250
14.78
13.38 (118)
45.90
28.50 (252)
2.95 (3.95)
4250
2198-H040-ERS
x
55.83
34.62 (306)
2198-H070-ERS
x
VPL-B1651C
2750
10.21
11.50 (102)
28.30
21.68 (192)
2.32 (3.11)
2750
2198-H025-ERS
x
29.29
22.45 (199)
2198-H040-ERS
x
VPL-B1651F
4750
17.60
11.43 (101)
45.90
18.02 (159)
4.38 (5.87)
4750
2198-H040-ERS
x
57.27
22.45 (199)
2198-H070-ERS
x
Bulletin VPL Motor Performance Specifications with Kinetix 5500 (400V-class operation) Drives (cont.)
Motor Cat. No.
Rated Speed,
max
rpm
System Continuous
Stall Current
A (0-pk)
System Continuous
Stall Torque
N•m (lb•in)
System Peak
Stall Current
A 0-pk
System Peak
Stall Torque
N•m (lb•in)
Motor Rated
Output
kW (Hp)
Speed at Motor
Rated Output
rpm
Kinetix 5500 Drives