Rockwell Automation 2198-Hxxx Kinetix 5500 Drive Systems Design Guide User Manual
Page 81

Rockwell Automation Publication GMC-RM009D-EN-P - June 2014
81
Kinetix 5500 Drive Systems
Performance Specifications with Frame 100 Linear Thrusters
Linear Thruster
Cat. No.
Velocity, max
460V AC
m/s
System Continuous
Stall Current
Amps 0-pk
System Continuous
Stall Force
N (lb)
System Peak
Stall Current
Amps 0-pk
System Peak
Stall Force
N (lb)
Rated Output
460V AC
kW
Kinetix 5500 Drives
(480V AC input)
LDAT-S102010-DD
x
3.4
5.7
456 (103)
21.0
1289 (290)
1.44
2198-H025-ERS
x
LDAT-S102020-DD
x
4.4
1.74
LDAT-S102030-DD
x
5.0
1.91
LDAT-S102040-DD
x
LDAT-S102050-DD
x
…
LDAT-S102090-DD
x
LDAT-S102010-ED
x
…
LDAT-S102090-ED
x
2.6
2.9
10.5
0.96
2198-H015-ERS
x
LDAT-S103010-DD
x
3.8
8.6
702 (158)
31.5
1935 (435)
2.41
2198-H040-ERS
x
LDAT-S103020-DD
x
5.0
2.93
LDAT-S103030-DD
x
…
LDAT-S103090-DD
x
LDAT-S103010-ED
x
…
LDAT-S103090-ED
x
1.8
2.9
10.5
0.92
2198-H015-ERS
x
LDAT-S104010-DD
x
4.1
11.5
929 (209)
42.0
2578 (580)
3.76
2198-H040-ERS
x
LDAT-S104020-DD
x
5.0
4.29
LDAT-S104030-DD
x
…
LDAT-S104090-DD
x
LDAT-S104010-ED
x
…
LDAT-S104090-ED
x
2.7
5.7
21.0
2.07
2198-H025-ERS
x
LDAT-S106010-DD
x
4.5
17.3
1403 (315)
63.0
3871 (870)
5.41
2198-H070-ERS
x
LDAT-S106020-DD
x
…
LDAT-S106090-DD
x
5.0
5.87
LDAT-S106010-ED
x
…
LDAT-S106090-ED
x
2.7
8.6
31.5
2.94
2198-H040-ERS
x